Simulação dinâmica por elementos finitos de ferimentos produzidos por armas de fogo na mandíbula humana [recurso eletrônico] = Dynamic simulation by finite element analysis in injuries produced by firearms in the human mandible
Sarah Teixeira Costa
DISSERTAÇÃO
Multilíngua
T/UNICAMP C823s
[Dynamic simulation by finite element analysis in injuries produced by firearms in the human mandible]
Piracicaba, SP : [s.n.], 2016.
1 recurso online ( 59 p.) : il., digital, arquivo PDF.
Orientadores: Felippe Bevilacqua Prado, Alexandre Rodrigues Freire
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Resumo: Complicações podem surgir em ferimentos de projéteis no crânio, especialmente na região maxilofacial, quando o projétil ou a arma não são encontrados na cena do crime. A fim de auxiliar nesses casos, este estudo realizou previamente uma revisão sistemática da literatura e estabeleceu um...
Ver mais
Resumo: Complicações podem surgir em ferimentos de projéteis no crânio, especialmente na região maxilofacial, quando o projétil ou a arma não são encontrados na cena do crime. A fim de auxiliar nesses casos, este estudo realizou previamente uma revisão sistemática da literatura e estabeleceu um modelo de elementos finitos de uma mandíbula e projéteis totalmente encamisados de calibre .40 Smith & Wesson (S&W), .380, e 9x19 mm Luger. As bases de dados Pubmed, Scopus e Web of Knowledge foram pesquisadas com as palavras chaves finite element gunshot, em busca de variáveis que afetam a precisão dos resultados. Em seguida, um modelo tridimensional de elementos finitos das estruturas ósseas da mandíbula foi estabelecido a partir de dados de tomografia computadorizada. A superfície tridimensional da mandíbula foi exportada no formato estereolitográfico(STL). O modelo tridimensional de CAD 3D da mandíbula foi construído a partir do STL. O modelo da mandíbula, bem como os modelos das munições, foram construídos com uma superfície livre não uniforme (NURBS) por um método de engenharia reversa. Foi descrita a distribuição de tensão von Mises na mandíbula, destacando a existência de áreas potencialmente fracas em algumas estruturas anatômicas, com foco em distâncias curtas (5 e 15 cm). Comparações da morfologia da superfície externa do orifício de entrada foram feitas. Foram selecionados 10 artigos que forneceram detalhes sobre as simulações das referências pesquisadas. Os resultados exibiram diferentes orifícios de entrada e diferentes padrões de tensões de von Mises para cada projétil disparado. A mandíbula foi mais afetada pelo calibre .40 S&W
Ver menos
Abstract: Complications may arise in gunshot wounds, especially to the maxillofacial region, when neither projectile nor gun is found at the crime scene. In order to help those cases, this study previously made systematic review and established a finite element model of a human mandible and fully...
Ver mais
Abstract: Complications may arise in gunshot wounds, especially to the maxillofacial region, when neither projectile nor gun is found at the crime scene. In order to help those cases, this study previously made systematic review and established a finite element model of a human mandible and fully metal-jacketed projectiles .40-caliber Smith & Wesson (S&W), .380-caliber, and 9x19-mm Luger. Data bases Pubmed, Scopus and Web of Knowledge were searched with the keywords finite element gunshot, in order to find variables that affect accuracy results. A 3D finite element model of the human mandible bone structures was established from computed tomography data.The 3D mandible surface was exported in stereolithographic (STL) format. The 3D CAD model of the human mandible was built from the STL. The mandible model, as well as the model of the ammunition, were constructed with freeform Non Uniform Rational B-Splines (NURBS) surfaces by a reverse engineering method. It was described the von Mises stress distribution in the human mandible, outlining the existence of potentially weak areas in some anatomical structures, focusing in close range fire distances (5 and 15 cm). Comparisons of entrance aperture morphological external surfaces were made. 10 references furnished details about how simulations occurred. The results displayed different entrance apertures and different von Mises stress patterns for each projectile shot. Mandible was most affected by .40-caliber S&W
Ver menos
Requisitos do sistema: Software para leitura de arquivo em PDF
Prado, Felippe Bevilacqua, 1980-
Orientador
Freire, Alexandre Rodrigues, 1985-
Coorientador
Okamoto, Roberta
Avaliador
Daruge Junior, Eduardo, 1960-
Avaliador
Simulação dinâmica por elementos finitos de ferimentos produzidos por armas de fogo na mandíbula humana [recurso eletrônico] = Dynamic simulation by finite element analysis in injuries produced by firearms in the human mandible
Sarah Teixeira Costa
Simulação dinâmica por elementos finitos de ferimentos produzidos por armas de fogo na mandíbula humana [recurso eletrônico] = Dynamic simulation by finite element analysis in injuries produced by firearms in the human mandible
Sarah Teixeira Costa