Development of new analytical method for preconcentration/speciation of inorganic antimony in bottled mineral water using FIA-HG AAS system and SiO2/Al2O3/SnO2 ternary oxide
Leandro Luan Goncalves de Oliveira, Guilherme Orlandin Ferreira, Fabio Antonio Cajamarca Suquila, Fernanda Garcia de Almeida, Leticia Alana Bertoldo, Mariana Gava Segatelli, Emerson Schwingel Ribeiro, Cesar Ricardo Teixeira Tarley
ARTIGO
Inglês
Agradecimentos: The authors acknowledge the financial support and fellowships of Coordenação de Aperfeiçoamento de Nível Superior (CAPES) (Project Pró-Forenses 3353/2014 Grant No 23038.007082/2014-03), Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) (307432/2017-3), Fundação...
Ver mais
Agradecimentos: The authors acknowledge the financial support and fellowships of Coordenação de Aperfeiçoamento de Nível Superior (CAPES) (Project Pró-Forenses 3353/2014 Grant No 23038.007082/2014-03), Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) (307432/2017-3), Fundação Araucária do Paraná (163/2014), SETI do Paraná, and Instituto Nacional de Ciência e Tecnologia de Bioanalítica (INCT) (FAPESP Grant No 2014/50867-3 and CNPq Grant No 465389/2014-7)
Ver menos
In the present paper, a new analytical preconcentration/speciation method for antimony species determination in bottled mineral water samples using the SiO2/Al2O3/SnO2 adsorbent was developed. The method is based on selective adsorption of Sb(III) ions by SiO2/Al2O3/SnO2 under a wide pH range...
Ver mais
In the present paper, a new analytical preconcentration/speciation method for antimony species determination in bottled mineral water samples using the SiO2/Al2O3/SnO2 adsorbent was developed. The method is based on selective adsorption of Sb(III) ions by SiO2/Al2O3/SnO2 under a wide pH range (2.5-7.5). Total antimony was determined with previous sample treatment using 0.1% (w/v) L-cysteine and the concentration of Sb(V) species was determined by the difference between total and Sb(III). The proposed method provided an analytical curve ranging from 0.50 to 5.00 mu g L-1 (r = 0.999), limit of detection (LD) of 0.17 mu g L-1 and preconcentration factor (PF) of 136-fold. The method exhibited tolerance to different metal ions and the accuracy was attested from addition and recovery tests (95.2-106.0%) in bottled mineral water samples using 2.0% (w/v) L-cysteine, as well as by analysis of certified material. Only Sb(III) species were determined in mineral water (0.54-1.04 mu g L-1)
Ver menos
CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQ
307432/2017-3
COORDENAÇÃO DE APERFEIÇOAMENTO DE PESSOAL DE NÍVEL SUPERIOR - CAPES
23038.007082/2014-03
FUNDAÇÃO ARAUCÁRIA DE APOIO AO DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO DO ESTADO DO PARANÁ - FA
163/2014
FUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESP
2014/50867-3
Fechado
Development of new analytical method for preconcentration/speciation of inorganic antimony in bottled mineral water using FIA-HG AAS system and SiO2/Al2O3/SnO2 ternary oxide
Leandro Luan Goncalves de Oliveira, Guilherme Orlandin Ferreira, Fabio Antonio Cajamarca Suquila, Fernanda Garcia de Almeida, Leticia Alana Bertoldo, Mariana Gava Segatelli, Emerson Schwingel Ribeiro, Cesar Ricardo Teixeira Tarley
Development of new analytical method for preconcentration/speciation of inorganic antimony in bottled mineral water using FIA-HG AAS system and SiO2/Al2O3/SnO2 ternary oxide
Leandro Luan Goncalves de Oliveira, Guilherme Orlandin Ferreira, Fabio Antonio Cajamarca Suquila, Fernanda Garcia de Almeida, Leticia Alana Bertoldo, Mariana Gava Segatelli, Emerson Schwingel Ribeiro, Cesar Ricardo Teixeira Tarley
Fontes
Food chemistry (Fonte avulsa) |