Title: Test Cell Simulating The Operating Conditions Of Water Electrolysers For The Evaluation Of Gas Evolving Electrocatalysts
Author: Teschke O.
Soares D.M.
Evora C.A.P.
Abstract: To evaluate promising anode, cathode, and separator materials in conditions similar to those present in a full-size water electrolyser, a test cell with electrode area of 10 cm2 was constructed. In order to operate with current densities as high as 1A cm-2 a 10 A pulsed galvanostat was developed and built which features a 'sample-hold' circuit to measure the IR-free electrode overvoltages and direct meter readings. © 1983 Chapman and Hall Ltd.
Editor: Kluwer Academic Publishers
Rights: fechado
Identifier DOI: 10.1007/BF00941610
Address: http://www.scopus.com/inward/record.url?eid=2-s2.0-0020752005&partnerID=40&md5=ecca790c49f09cfebb722b6c652c51d5