Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/96720
Type: Artigo de periódico
Title: Quality Control In Potentiometric Determination Of Acid Volatile Sulfides (avs) Using Standard Addition [controle Da Qualidade Na Determinação Potenciométrica De Sulfetos Volatilizáveis Por Acidificação (sva) Utilizando Adições De Padrão]
Author: Fagnani E.
Guimaraes J.R.
Grassi M.T.
Fadini P.S.
Abstract: This paper presents a quality assurance and quality control protocol in order to ensure the reliability of analytical results for the determination of acid volatile sulfides in environmental samples by potentiometry. The monitoring of the ion selective sensor readings must be realized continually and particularly in this situation where the analyte is susceptible to transformation and volatilization. Potentiometry with the standard addition was presented as a rapid, accurate, precise, feasible as well as a low cost technique. Concentrations of the analyte in the range of 0.49 to 1.02 mg L -1 were tested with percentage recoveries varying from 89 to 113%.
Editor: 
Rights: aberto
Identifier DOI: 10.1590/S0100-40422012000400033
Address: http://www.scopus.com/inward/record.url?eid=2-s2.0-84862851809&partnerID=40&md5=eef5626d2acffd5b9dcd1b7ed97f7b1a
Date Issue: 2012
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.