Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/95422
Type: Artigo de periódico
Title: Fluxo De Carga Desacoplado Trifasico
Author: Garcia Ariovaldo Verandio
Zago Maria Goretti
Abstract: Power system single-phase model assumes that the generation, transmission and distribution systems are perfectly balanced. The great appeal of this type of model is its simplicity, for all the calculations become quite simple, when compared with the three-phase model, and the results obtained are well suited for most applications. There are cases, however, in which its results may not be accurate enough, as it may happen with distribution system analysis (unbalanced loads), non-transposed transmission lines, large mutual impedances between lines, etc. These problems require a more accurate three-phase model. This paper extends the decoupling theory of Monticelli et alii (1990) in order to obtain a fast decoupled three-phase load flow which is suited for distribution power system analysis.
Editor: Sociedade Brasileira de Automatica, Sao Paulo, Brazil
Rights: aberto
Identifier DOI: 
Address: http://www.scopus.com/inward/record.url?eid=2-s2.0-0029708923&partnerID=40&md5=5f841767b35554d41b1462eda4f6c6b0
Date Issue: 1996
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item: