Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/95412
Type: Artigo de periódico
Title: Use Of The Modified Implant Test As A Manner Of Determining Susceptibility To Reheat Cracking [a Utilização Do Teste De Implante Modificado Como Forma De Determinação Da Suscetibilidade à Trinca De Reaquecimento]
Author: Martins F.
Trevisan R.D.E.
Abstract: Reheat crackings occur, in general, in the heat affected zone of welded joints of high strength low alloy structural steel during post welding stress relief heat treatment (PWHT). The modified implant test showed to be an effective form of evaluating susceptibility to Reheat Cracking. The present work focus on the design and construction of a modified implant test equipment. The equipment is used to test the reheat cracking susceptibility of a high strength low alloy steel. The results showed that the proposed equipment presents good reliability. The tested steel is highly susceptible to reheat cracking.
Editor: 
Rights: aberto
Identifier DOI: 
Address: http://www.scopus.com/inward/record.url?eid=2-s2.0-5844306274&partnerID=40&md5=a8592f9fa7cfd5e169f1f351324a9ad4
Date Issue: 1996
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.