Title: Long rotating coil system based on stretched tungsten wires for insertion device characterization
Author: Tosin, G
Citadini, JF
Conforti, E
Abstract: A very precise rotating coil was developed using stretched tungsten wires in a new geometric arrangement for the accurate magnetic characterization of insertion devices (IDs). Many sources of errors were analyzed, and a procedure to evaluate coil defects by means of a dipolar magnetic field is presented. Tests were performed in a 2-T planar wiggler, which is 2.8 m long, with 180 mm of period, of the Brazilian Synchrotron Light Source (LNLS). The advantages of using the tungsten wires and the measurement repeatability and accuracy are also discussed.
Subject: insertion devices (IDs)
magnetic characterization
rotating coil
tungsten wires
wiggler
Country: EUA
Editor: Ieee-inst Electrical Electronics Engineers Inc
Rights: fechado
Identifier DOI: 10.1109/TIM.2008.922093
Date Issue: 2008
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
WOS000259541100027.pdf622.03 kBAdobe PDFView/Open