Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/79557
Type: Artigo de periódico
Title: Determination of molybdenum in steel by adsorptive stripping voltammetry in a homogeneous ternary solvent system
Author: de Andrade, JC
de Almeida, AM
Coscione, AR
Aleixo, LM
Abstract: A new alternative approach for the determination of molybdenum in steel is proposed, using adsorptive stripping voltammetry (AdSV). The determinations are performed in a homogeneous ternary solvent system (HTSS) composed of N,N-dimethylformamide, ethanol and water, with alpha -benzoinoxime (alpha BO) as the complexing agent and a sodium acetate-acetic acid buffer as the support electrolyte. The HTSS composition was optimized by mixture design modelling. The AdSV measurements were performed in the differential pulse mode using an accumulation potential of -1050 mV. Under these optimized experimental conditions, the Mo(vi)-alpha BO reduction current peak potential is observed at potentials near -1250 mV, much lower than those usually reported, and the calibration plot follows the polynomial equation I = 0.359 + 0.265 [C-Mo(vi)] - 0.015 [C-Mo(iv)](2) (r(2) = 0.997), for Mo concentrations up to 10.0 mug L-1. There is a linear range in this calibration plot for Mo(vi) concentrations up to 0.20 mug L-1, defined by the equation I = 0.353 + 0.385 [C-Mo(vi)] (r(2) = 0.980). In both cases, I is the absolute value for the current in muA and C-Mo(vi) is the concentration of Mo in mug L-1. The detection limit for this linear concentration range was estimated as 20 pg L-1. A RSD of 0.43% is associated with the signals at a Mo(vi) level of 0.72 mug L-1. From the common method-interfering species tested, only iron at Fe/Mo(vi) ratios above 500 and vanadium and tungsten at M/Mo(vi) ratios above 100 appear to affect the analytical response significantly. Phosphorous may also reduce the analytical signal at P/Mo(vi) ratios above 100, due to the formation of the competitive P-Mo complex. The suggested routine procedure was tested by analyzing four stainless steel samples and the results compared well with the ICP-AES measurements. The higher sensitivity of this method permits direct determination of Mo(vi) in steels, eliminating the need of analyte concentration or separation steps in the sample processing procedure.
Country: Inglaterra
Editor: Royal Soc Chemistry
Rights: aberto
Date Issue: 2001
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
WOS000168990800032.pdf72.56 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.