Abstract: This study evaluated fatigue strength of CP-Ti laser-welded joints. Sixty (20/diameter) CP-Ti casted dumbbell rods with diameters of 1.5, 2.0, and 3.5 mm were sectioned and welded using two joint openings (0.0 (00) and 0.6 mm (06)). Six groups were formed, amounting to a total of 9 (n=10) with inclusion of intact groups. Welding was executed using 360 V/8 ms (1.5 and 2.0 mm) and 380 V/9 ins (3.5 mm). Joints were finished, polished, and submitted to radiographic examination to visually analyze presence of porosity (PP). Specimens were submitted to cyclic tests, and the number of cycles until failure (NC) was recorded. Fractured surfaces were examined by SEM. Kruskal-Wallis and Dunn (alpha=0.05) tests demonstrated that NC was lower for all diameters with 06, and for 3.5 mm/00. NC and PP were found to have a negative correlation (Spearman Coefficient). For CP-Ti frameworks with thin diameters, laser welding is better when structures are juxtaposed.
Subject: Titanium
Laser welding
Fatigue
Material resistance
Mechanical cycling
Country: Japão
Editor: Japanese Soc Dental Materials Devices
Rights: fechado
Identifier DOI: 10.4012/dmj.2011-112
Date Issue: 2011
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
WOS000299863100013.pdf1.52 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.