Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/66659
Type: Artigo de periódico
Title: Factorial design and doehlert matrix in optimization of flow system for preconcentration of copper on polyurethane foam loaded with 4-(2-pyridylazo)-resorcinol
Author: Tarley, CRT
dos Santos, WNL
dos Santos, CM
Arruda, MAZ
Ferreira, SLC
Abstract: The present paper describes a flow preconcentration system for copper determination by flame atomic absorption spectrometry (FAAS) based on the sorption of Cu(II) ions onto a mini-column of polyurethane foam (PUF) loaded with a chromogenic reagent [4-(2-pyridylazo)resorcinol (PAR)]. The variables associated with flow preconcentration system performance, such as pH, buffer concentration (BC), and sampling flow rate (SF), were optimised using a full factorial (2 3) design plus a central point and Doehlert matrix. The results obtained, based on the Pareto chart and analysis of variance (ANOVA), demonstrated that pH and BC, as well as the interaction (pH x BC) are statistically significant at the 95% confidence level. By using 20 mL of sampling volume the proposed method, under conditions optimised by the Doehlert matrix (formation of Cu(II)-PAR (1: 2) complex at pH 6.4, 0.017 mol L-1 phosphate BC, and 10 mL min(-1) SF), allows to determine Cu(II) ions with a detection limit of 0.35 mug L-1 and precision (n = 8) as relative standard deviation (RSD) of 3.2 and 1.1 for copper solutions containing 10 and 30 mug L-1, respectively. Also, a satisfactory linear range (1.2-40 [mug L-1), an enrichment factor of 105 and a sample throughput of 28 hr(-1) were achieved. Interference studies showed that the PUF-PAR mini-column retains Cu(H) ions in the presence of several transition and alkali metals without presenting interferences. The method was applied for copper determination in water samples (mineral and tap water) and high salt aqueous samples (physiological serum containing 0.9% (m/v) NaCI). The validation of the method was checked by analysing the Cu(II) content in the samples, as well as from analyte addition. The recoveries ranged from 91.0% to 101.1%.
Subject: doehlert matrix
flow preconcentration system
polyurethane foam
4-(2-pyridylazo)-resorcinol
copper
Country: EUA
Editor: Marcel Dekker Inc
Rights: fechado
Identifier DOI: 10.1081/AL-120035909
Date Issue: 2004
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
WOS000221935400013.pdf282.75 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.