Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/66407
Type: Artigo de periódico
Title: Experimental-numerical comparison of the cantilever MEMS frequency shift in presence of a residual stress gradient
Author: Ballestra, A
Soma, A
Pavanello, R
Abstract: The dynamic characterization of a set of gold micro beams by electrostatic excitation in presence of residual stress gradient has been studied experimentally. A method to determine the micro-cantilever residual stress gradient by measuring the deflection and curvature and then identifying the residual stress model by means of frequency shift behaviour is presented. A comparison with different numerical FEM models and experimental results has been carried out, introducing in the model the residual stress of the structures, responsible for an initial upward curvature. Dynamic spectrum data are measured via optical interferometry and experimental frequency shift curves are obtained by increasing the dc voltage applied to the specimens. A good correspondence is pointed out between measures and numerical models so that the residual stress effect can be evaluated for different configurations.
Subject: frequency shift
residual stress gradient
micro cantilever
MEMS
Country: Suíça
Editor: Molecular Diversity Preservation International-mdpi
Rights: aberto
Identifier DOI: 10.3390/s8020767
Date Issue: 2008
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
WOS000253779100010.pdf547.99 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.