Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/60754
Type: Artigo de periódico
Title: Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluation
Author: Livani, B
Belangero, W
Andrade, K
Zuiani, G
Pratali, R
Abstract: In the last few years there has been great interest in minimally invasive plate osteosynthesis (MIPO) in the treatment of humeral shaft fractures. None of these studies showed the anatomical relationship between the radial nerve and the material of the implant in vivo. We performed postoperative ultrasonographic measurement of the distance between the radial nerve and the material implanted using the MIPO technique. Nineteen patients underwent postoperative ultrasound examinations. Group A comprised midshaft fractures and group B distal third fractures. The point of greatest proximity between the radial nerve and the implant was measured. In group A the distance was between 1.6 and 19.6 mm (mean: 9.3 mm) and in group B between 1.0 and 8.1 mm (mean: 4.0 mm). The ultrasound findings reveal that the radial nerve is quite close to the implant material, especially in the transition between the third and fourth quarters of the humeral shaft.
Country: EUA
Editor: Springer
Rights: fechado
Identifier DOI: 10.1007/s00264-008-0616-x
Date Issue: 2009
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
WOS000272174300041.pdf212.7 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.