Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/55326
Type: Artigo de periódico
Title: Baseline resolution of isomers by traveling wave ion mobility mass spectrometry: investigating the effects of polarizable drift gases and ionic charge distribution
Author: Lalli, PM
Corilo, YE
Fasciotti, M
Riccio, MF
de Sa, GF
Daroda, RJ
Souza, GHMF
McCullagh, M
Bartberger, MD
Eberlin, MN
Campuzano, IDG
Abstract: We have studied the behavior of isomers and analogues by traveling wave ion mobility mass spectrometry (TWIM-MS) using drift-gases with varying masses and polarizabilities. Despite the reduced length of the cell (18cm), a pair of constitutional isomers, N-butylaniline and para-butylaniline, with theoretical collision cross-section values in helium ((He)) differing by as little as 1.2 angstrom(2) (1.5%) but possessing contrasting charge distribution, showed baseline peak-to-peak resolution (Rp-p) for their protonated molecules, using carbon dioxide (CO2), nitrous oxide (N2O) and ethene (C2H4) as the TWIM drift-gas. Near baseline Rp-p was also obtained in CO2 for a group of protonated haloanilines (para-chloroaniline, para-bromoaniline and para-iodoaniline) which display contrasting masses and theoretical (He), which differ by as much as 15.7 angstrom(2) (19.5%) but similar charge distributions. The deprotonated isomeric pair of trans-oleic acid and cis-oleic acid possessing nearly identical theoretical (He) and (N2) as well as similar charge distributions, remained unresolved. Interestingly, an inversion of drift-times were observed for the 1,3-dialkylimidazolium ions when comparing He, N-2 and N2O. Using density functional theory as a means of examining the ions electronic structure, and He and N-2-based trajectory method algorithm, we discuss the effect of the long-range charge induced dipole attractive and short-range Van der Waals forces involved in the TWIM separation in drift-gases of differing polarizabilities. We therefore propose that examining the electronic structure of the ions under investigation may potentially indicate whether the use of more polarizable drift-gases could improve separation and the overall success of TWIM-MS analysis. Copyright (c) 2013 John Wiley & Sons, Ltd.
Subject: ion mobility
polarizable drift-gas
isomer separation
Country: EUA
Editor: Wiley-blackwell
Rights: fechado
Identifier DOI: 10.1002/jms.3245
Date Issue: 2013
Appears in Collections:Artigos e Materiais de Revistas Científicas - Unicamp

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.