Title: Cardiovascular Simulator Improvement: Pressure Versus Volume Loop Assessment
Author: FONSECA, Jeison
ANDRADE, Aron
NICOLOSI, Denys E. C.
BISCEGLI, Jose F.
LEME, Juliana
LEGENDRE, Daniel
BOCK, Eduardo
LUCCHI, Julio Cesar
Abstract: This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made.
Subject: Mock-loop system
Cardiovascular simulation
Ventricular assist device
Intraventricular pressure versus intraventricular volume loop
Country: Estados Unidos
Editor: WILEY-BLACKWELL
Rights: fechado
Identifier DOI: 10.1111/j.1525-1594.2011.01266.x
Address: http://apps.isiknowledge.com/InboundService.do?Func=Frame&product=WOS&action=retrieve&SrcApp=EndNote&UT=000290805200007&Init=Yes&SrcAuth=ResearchSoft&mode=FullRecord
http://dx.doi.org/10.1111/j.1525-1594.2011.01266.x
Date Issue: 2011
Appears in Collections:FEM - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
art_FONSECA_Cardiovascular_Simulator_Improvement_Pressure_Versus_Volume_Loop_2011.pdfpublished version411.38 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.