Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/359291
Type: DISSERTAÇÃO DIGITAL
Degree Level: Mestrado
Title: Estaca injetada instrumentada tipo Incopile : avaliação do comportamento à compressão em solo tropical da região de Campinas/SP
Title Alternative: Instrumented inject piles Incopile type : evaluation of compression behavior in tropical soil in the region of Campinas/SP
Author: Castro Neto, Joaquim Ribeiro de, 1995-
Advisor: Albuquerque, Paulo José Rocha de, 1964-
Abstract: Resumo: Este trabalho avalia o comportamento à compressão de duas estacas injetadas por meio de prova de carga estática lenta com instrumentação em profundidade. Essas estacas têm como armadura principal um tubo de aço API N-80, o qual também é utilizado durante a perfuração. As estacas possuíam 0,30 m de diâmetro, e comprimentos de 21,0 m e 19,4 m. Foram executadas no Campo Experimental III da Unicamp, o qual apresenta camada superficial de argila arenosa (porosa e colapsível) seguida de camada de silte arenoso. Para as cargas máximas dos ensaios, 2210 kN e 2470 kN, não foi mobilizada resistência de ponta e o atrito lateral obtido foi, respectivamente, 112 kPa e 135 kPa. As provas de carga (lentas) não mostraram ruptura nítida, sendo a força resistente última estimada a partir de métodos de extrapolação da curva carga-recalque. Os resultados foram comparados com estimativas obtidas por métodos semiempíricos de capacidade de carga, mostrando que a maioria deles superestimaram a resistência de ponta, sendo a estimativa dada pelo método da FHWA (2005) a mais assertiva. Por fim, a comparação com outros tipos de estacas executadas no mesmo local, tais como hélice contínua e raiz, mostrou que as estacas injetadas desta pesquisa tiveram melhor desempenho no que se refere à mobilização de atrito

Abstract: This research evaluates the compression behavior of two micropiles using a slow static load test with depth instrumentation. These piles have as main reinforcement an API N-80 steel tube, which is also used during drilling. The piles were 0.30 m in diameter, with lengths of 21.0 m and 19.4 m. They were carried out at Unicamp Experimental Field III, which has a superficial layer of sandy clay (porous and collapsible), followed by a layer of sandy silt. For the maximum loads of the tests, 2210 kN and 2470 kN, tip resistance was not mobilized, and the lateral friction obtained was, respectively, 112 kPa and 135 kPa. The load tests (slow) did not show a plunging failure, so the ultimate resistant force was estimated using methods of extrapolation of the load-settlement curve. The results were compared with estimates obtained by semi-empirical methods of load capacity, showing that most of them overestimated the tip resistance and underestimated the lateral friction, being the estimate given by the method of FHWA (2005) the most assertive. Finally, the comparison with other types of piles carried out in the same location, such as continuous flight auger and root pile, showed that the micropiles of this research had a better performance in terms of friction mobilization
Subject: Fundações (Engenharia)
Instrumentação
Solos
Language: Português
Editor: [s.n.]
Citation: CASTRO NETO, Joaquim Ribeiro de. Estaca injetada instrumentada tipo Incopile: avaliação do comportamento à compressão em solo tropical da região de Campinas/SP. 2021. 1 recurso online (158 p.) Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Campinas, SP.
Date Issue: 2021
Appears in Collections:FEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
CastroNeto_JoaquimRibeiroDe_M.pdf3.91 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.