Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/356053
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.contributor.authorunicampPaula, Marcelo Vinícius de-
dc.contributor.authorunicampBarros, Tárcio André dos Santos-
dc.typeArtigopt_BR
dc.titleA new flux linkage estimation with drift cancellation technique for switched reluctance machinespt_BR
dc.contributor.authorPaula, Marcelo Vinícius de-
dc.contributor.authorBarros, Tárcio André dos Santos-
dc.subjectModelagempt_BR
dc.subject.otherlanguageModelingpt_BR
dc.description.abstractAssessing the flux linkage is an important feature for electric machines, including switched reluctance machines. However, sensor calibration errors and noise impose a problem known as drift, which is caused by the integration process used to estimate the flux linkage. This paper proposes a flux linkage estimation with a drift cancellation technique. The technique accounts for the switched reluctance machine’s working and driving principles. Simulation and experimental results are used to validate the proposed method. Additionally, a goodness-of-fit analysis is performed to support the outcomes. A R2 factor of 0.9823 is found between the experimentally and simulation-estimated flux linkage. The results indicate that the method works properly and may be further used in control techniques and iron losses estimationpt_BR
dc.relation.ispartofElectronicspt_BR
dc.publisher.cityBaselpt_BR
dc.publisher.countrySuíçapt_BR
dc.publisherMDPI AGpt_BR
dc.date.issued2020-
dc.date.monthofcirculationFeb.pt_BR
dc.language.isoengpt_BR
dc.description.volume9pt_BR
dc.description.issuenumber3pt_BR
dc.rightsFechadopt_BR
dc.sourceWOSpt_BR
dc.identifier.eissn2079-9292pt_BR
dc.identifier.doi10.3390/electronics9030405pt_BR
dc.identifier.urlhttps://www.mdpi.com/2079-9292/9/3/405pt_BR
dc.description.sponsorshipCONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQpt_BR
dc.description.sponsorshipFUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESPpt_BR
dc.description.sponsordocumentnumberNão tempt_BR
dc.description.sponsordocumentnumber2017/21640-9pt_BR
dc.date.available2021-02-18T13:07:18Z-
dc.date.accessioned2021-02-18T13:07:18Z-
dc.description.provenanceSubmitted by Susilene Barbosa da Silva (susilene@unicamp.br) on 2021-02-18T13:07:18Z No. of bitstreams: 0. Added 1 bitstream(s) on 2021-05-24T19:06:33Z : No. of bitstreams: 1 000524079100026.pdf: 1555171 bytes, checksum: 138670cd75adcfa56825fefb8d7ac87c (MD5)en
dc.description.provenanceMade available in DSpace on 2021-02-18T13:07:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2020en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/356053-
dc.contributor.departmentSem informaçãopt_BR
dc.contributor.departmentDepartamento de Sistemas Integradospt_BR
dc.contributor.unidadeFaculdade de Engenharia Mecânicapt_BR
dc.subject.keywordSwitched reluctance machines;pt_BR
dc.subject.keywordFlux linkage estimation;pt_BR
dc.identifier.source000524079100026pt_BR
dc.creator.orcid0000-0002-2213-608pt_BR
dc.creator.orcidsem informaçãopt_BR
dc.type.formArtigopt_BR
dc.identifier.articleid405pt_BR
Appears in Collections:FEM - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
000524079100026.pdf1.52 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.