Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/355544
Type: Artigo
Title: Influence of diamondlike carbon coating of screws on axial tightening force and stress distribution on overdenture bar frameworks with different fit levels and materials
Author: Santos, Mateus Bertolini Fernandes dos
Bacchi, Atais
Consani, Rafael Leonardo Xediek
Correr-Sobrinho, Lourenço
Abstract: The aim of this study was to evaluate the axial tightening force applied by conventional and diamondlike carbon (DLC)–coated screws and to verify, through three-dimensional finite element analysis (FEA), the stress distribution caused by different framework materials and prosthetic screws in overdenture frameworks with different misfit levels. Materials and Methods: The axial tightening force applied by the screw was evaluated by means of a titanium matrix connected to a load cell. Conventional titanium or DLC-coated screws were tightened with a digital torque wrench, and the load values were recorded. The values were applied in an FEA to a bar-clip attachment system connected to two 4.0 × 11-mm external-hexagon titanium implants placed in an anterior edentulous arch. DLC-coated and conventional screws were modeled with their respective axial forces obtained on the experimental evaluation for three bar framework materials (titanium, nickel-chromium, and cobalt-chromium) and three levels of misfit (100, 150, and 200 μm). Von Mises stresses for prosthetic components and maximum principal stress and microstrains (maximum principal strains) for bone tissue were measured. Results: The mean force applied by the conventional screw was 25.55 N (± 1.78); the prosthetic screw coated with a DLC layer applied a mean force of 31.44 N (± 2.11), a statistically significant difference. In the FEA, the DLC screw led to higher stresses on the framework; however, the prosthetic screw suffered lower stress. No influence of screw type was seen in the bone tissue. Conclusion: Titanium frameworks reduced the stress transmitted to the bone tissue and the bar framework but had no influence on the screws. Higher misfit values resulted in an increased stress/strain in bone tissue and bar framework, which was not the case for retention screws
Subject: Análise de elementos finitos
Country: Estados Unidos
Editor: Quintessence
Rights: Fechado
Identifier DOI: 10.11607/jomi.3730
Address: http://quintpub.com/journals/omi/abstract.php?iss2_id=1330&article_id=15647&article=5
Date Issue: 2015
Appears in Collections:FOP - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
000367251300004.pdf423.24 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.