Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/351231
Type: DISSERTAÇÃO DIGITAL
Degree Level: Mestrado
Title: Optimized reactive power capability of wind power plants with tap-changing transformers : Capacidade de potência reativa otimizada das usinas eólicas usando comutaçao de taps dos transformadores
Title Alternative: Capacidade de potência reativa otimizada das usinas eólicas usando comutaçao de taps dos transformadores
Author: Alcahuaman Villanueva, Hever, 1992-
Advisor: Dotta, Daniel, 1978-
Abstract: Resumo: Com os recentes avanços na eletrônica de potência para turbinas eólicas, as usinas eólicas tornaram-se ativos valiosos para o suporte de potência reativa de sistemas elétricos de potência. Neste trabalho, apresentamos uma metodologia para otimizar a capacidade de potência reativa das usinas eólicas do ponto de vista de acoplamento comum. Para esse fim, a metodologia proposta determina a configuração dos transformadores de comutação na usina eólica que maximiza a quantidade de potência reativa que a usina eólica pode consumir ou injetar na rede, considerando níveis incertos de geração de energia eólica e magnitude da tensão no ponto de acoplamento comum. O problema da capacidade de potência reativa otimizada é inicialmente formulado como um modelo de programação não linear inteiro misto. Em seguida, um conjunto de técnicas eficientes de linearização é usado para obter um modelo de programação linear inteiro misto que pode ser resolvido por meio de solucionadores de programação matemática prontos para uso. Os resultados demonstram que o modelo proposto é um método escalável, flexível e preciso para maximizar a capacidade de potência reativa da usina eólica, como visto no ponto de acoplamento comum

Abstract: With the recent advancements in power electronics for wind turbines, wind power plants (WPPs) have become valuable assets for reactive power support of bulk power systems. In this paper, we present a methodology to optimize the WPP's reactive power capability as seen from the point of common coupling (PCC). To this end, the proposed methodology determines the configuration of the tap-changing transformers within the WPP that maximizes the amount of reactive power the WPP can either consume or inject into the network, considering uncertain levels of wind power generation and voltage magnitude at the PCC. The optimized reactive power capability (ORPC) problem is initially formulated as a mixed-integer nonlinear programming (MINLP) model. Then, a set of efficient linearization techniques are used to obtain a mixed-integer linear programming (MILP) model that can be solved via off-the-shelf mathematical programming solvers. The results demonstrate that the proposed MILP model is a scalable, flexible and accurate method to maximize the reactive power capability of WPP as seen from the PCC
Subject: Potência reativa (Engenharia elétrica)
Programação linear inteira mista
Energia eólica
Eletrônica de potência
Fluxo de carga elétrica
Language: Inglês
Editor: [s.n.]
Citation: ALCAHUAMAN VILLANUEVA, Hever. Optimized reactive power capability of wind power plants with tap-changing transformers: Capacidade de potência reativa otimizada das usinas eólicas usando comutaçao de taps dos transformadores . 2020. 1 recurso online ( 107 p.) Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação, Campinas, SP.
Date Issue: 2020
Appears in Collections:FEEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
Villanueva_HeverAlcahuaman_M.pdf3.79 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.