dc.titleComparison between traditional single-phase auto reclosing and adaptive technique based on harmonic content measurementpt_BR
dc.contributor.authorDias, Ozenir-
dc.contributor.authorTavares, Maria Cristina-
dc.subjectEnergia elétrica - Transmissãopt_BR
dc.subject.otherlanguageElectric power distributionpt_BR
dc.description.abstractThis study presents the results of single-phase auto reclosing technique tests, comparing the performance of traditional procedure and fast adaptive procedure. The last is based on the measurement of voltage harmonic content on the transmission line faulty phase terminals. The transmission system used was modelled on the real-time digital simulator with a distance relay and a quality meter to more realistically implement the reclosing techniques. The studied system was based on an actual Brazilian 500 kV transmission system. This study highlights the advantages of using the adaptive technique opposite to the use of traditional manoeuvrept_BR
dc.relation.ispartofIET generation, transmission and distributionpt_BR
dc.relation.ispartofabbreviationIET gener., transm. distrib.pt_BR
dc.publisher.cityStevenagept_BR
dc.publisher.countryReino Unidopt_BR
dc.publisherInstitution of Engineering and Technologypt_BR
dc.date.issued2017-
dc.language.isoengpt_BR
dc.description.volume11pt_BR
dc.description.issuenumber4pt_BR
dc.description.firstpage905pt_BR
dc.description.lastpage914pt_BR
dc.rightsFechadopt_BR
dc.sourceWOSpt_BR
dc.identifier.issn1751-8687pt_BR
dc.identifier.eissn1751-8695pt_BR
dc.identifier.doi10.1049/iet-gtd.2016.0849pt_BR
dc.identifier.urlhttps://ieeexplore.ieee.org/document/7876914pt_BR
dc.description.sponsorshipCONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQpt_BR
dc.description.sponsorshipFUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESPpt_BR
dc.description.sponsorshipFUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DO AMAZONAS - FAPEAMpt_BR
dc.description.sponsordocumentnumbernão tempt_BR
dc.description.sponsordocumentnumbernão tempt_BR
dc.description.sponsordocumentnumbernão tempt_BR
dc.date.available2020-08-13T19:33:56Z-
dc.date.accessioned2020-08-13T19:33:56Z-
dc.description.provenanceSubmitted by Mariana Aparecida Azevedo (mary1@unicamp.br) on 2020-08-13T19:33:56Z No. of bitstreams: 0. Added 1 bitstream(s) on 2021-01-08T19:03:01Z : No. of bitstreams: 1 000398589300010.pdf: 1735814 bytes, checksum: 472c992430be84be743243c1087962f5 (MD5)en
dc.description.provenanceMade available in DSpace on 2020-08-13T19:33:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2017en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/347357-
dc.contributor.departmentsem informaçãopt_BR
dc.contributor.departmentDepartamento de Sistemas e Energiapt_BR
dc.contributor.unidadeFaculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.contributor.unidadeFaculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.subject.keywordPower transmission faultspt_BR
dc.subject.keywordPower transmission linespt_BR
dc.subject.keywordPower transmission protectionpt_BR
dc.subject.keywordPower transmission reliabilitypt_BR
dc.subject.keywordRelay protectionpt_BR
dc.identifier.source000398589300010pt_BR
dc.creator.orcid0000-0001-8839-336pt_BR
dc.creator.orcid0000-0001-9030-6764pt_BR
dc.type.formArtigo de pesquisapt_BR
Appears in Collections:FEEC - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
000398589300010.pdf1.7 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.