Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/346061
Type: Artigo
Title: Os perigos advindos de válvulas de ar em sistemas adutores e duas soluções eficazes testadas computacionalmente
Title Alternative: The perils of air valves in water mains and two effective solutions tested computationally
Author: Tasca, Elias Sebastião Amaral
Luvizotto Junior, Edevar
Dalfré Filho, José Gilberto
Abstract: Neste trabalho, mostrou-se a importância do controle da expulsão de ar por meio de válvulas ventosas. Como pano de fundo, fez-se breve exposição sobre válvulas ventosas e sobre transitórios hidráulicos. A adutora do estudo de caso é composta por tubos de PVC DN 200 mm e tem 1570,0 m de extensão. Simulou-se, computacionalmente, o transitório hidráulico nesta adutora devido ao desligamento repentino do sistema de bombeamento. Esse transitório gerou sobrepressões demasiadamente elevadas. Nesse contexto, o uso de válvulas ventosas sem controle de expulsão de ar acarretou em pressões máximas até 80,8 mH2 O (44,8 mH2O na média) maiores do que na situação sem instalação de válvulas ventosas. Duas maneiras para controlar a expulsão de ar foram sugeridas. Para uma dessas maneiras, propõe-se um dispositivo com placa de orifício. Com o controle da expulsão de ar, conseguiu-se obter pressões máximas abaixo dos limites definidos pelas características da adutora
metadata.dc.description.abstractalternative: In the present paper, the importance of controlled air expulsion through air valves is substantiated. A brief exposition about air valves and about hydraulic transients is presented. The water main of the case study is composed of PVC DN 200 mm and has a length of 1570.0 m. It was simulated, computationally, the hydraulic transient that comes from the abrupt turning off of the pumping system. This transient generated overpressures greater than the permitted ones. In this context, the use of air valves without air expulsion control generated maximum pressures even 80.8 mH2 O (44.8 mH2O on verage) greater than in the situation without any air valves. Two ways to control air expulsion were presented. For one of these ways, a device with an orifice plate was proposed. With air expulsion control, it was possible to obtain maximum pressures bellow the maximum allowed pressure
Subject: Transitórios hidraulicos
Country: Brasil
Editor: Companhia de Saneamento Básico do Estado de São Paulo
Rights: Aberto
Identifier DOI: 10.4322/dae.2019.001
Address: http://revistadae.com.br/site/artigos/215
Date Issue: 2019
Appears in Collections:FEC - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
104322dae2019001.pdf548.71 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.