Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/345933
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.contributor.authorunicampBusarello, Tiago Davi Curi-
dc.contributor.authorunicampPomilio, José Antenor-
dc.typeArtigopt_BR
dc.titlePassive filter aided by shunt compensators based on the conservative power theorypt_BR
dc.contributor.authorBusarello, Tiago Davi Curi-
dc.contributor.authorPomilio, Jose Antenor-
dc.contributor.authorSimoes, Marcelo Godoy-
dc.subjectEnergia elétrica - Distribuiçãopt_BR
dc.subject.otherlanguageElectric power distributionpt_BR
dc.description.abstractPassive filters are widely used in electrical system for power quality improvements. Their first installations from 1940 s and their advantages make them an attractive and standard solution up to nowadays. However, passive filters have their filtering characteristics deteriorated due to parameter variation caused by aging or temperature. In addition, a capacitor bank for power factor correction is designed for specific loads and may not supply the right amount of reactive power when loads keep being added or changed. When these issues make the passive filter and the capacitor bank incapable to keep the system operating within acceptable level of power quality, an inconvenience arises and a solution must be provided. A common one is to replace both of them either by new elements or by active power compensators. However, replacing the passive filter and the capacitor bank may not be economically feasible, because they belong to a past investment. This paper presents a solution to overcome such inconvenience keeping the passive filter and the capacitor bank installed and unchanged. It consists of installing two shunt compensators specially designed for performing what the passive filter and the capacitor bank are incapable to do. The result is a reduced processed power in the compensators. The generation of the references is based on conservative power theory (CPT). A case study is presented to prove the compensators' efficacy and the power quality improvementpt_BR
dc.relation.ispartofIeee Transactions on industry applicationspt_BR
dc.publisher.cityPiscataway, NJpt_BR
dc.publisher.countryEstados Unidospt_BR
dc.publisherInstitute of Electrical and Electronics Engineerspt_BR
dc.date.issued2016-
dc.date.monthofcirculationJuly/Aug.pt_BR
dc.language.isoengpt_BR
dc.description.volume52pt_BR
dc.description.issuenumber4pt_BR
dc.description.firstpage3340pt_BR
dc.description.lastpage3347pt_BR
dc.rightsFechadopt_BR
dc.sourceWOSpt_BR
dc.identifier.issn0093-9994pt_BR
dc.identifier.eissn1939-9367pt_BR
dc.identifier.doi10.1109/TIA.2016.2544829pt_BR
dc.identifier.urlhttps://ieeexplore.ieee.org/document/7438850pt_BR
dc.description.sponsorshipCONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQpt_BR
dc.description.sponsorshipFUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESPpt_BR
dc.description.sponsordocumentnumber303036/2010-9pt_BR
dc.description.sponsordocumentnumber2012/23914-5pt_BR
dc.date.available2020-07-22T17:42:03Z-
dc.date.accessioned2020-07-22T17:42:03Z-
dc.description.provenanceSubmitted by Mariana Aparecida Azevedo (mary1@unicamp.br) on 2020-07-22T17:42:03Z No. of bitstreams: 0. Added 1 bitstream(s) on 2021-01-08T19:02:27Z : No. of bitstreams: 1 000380065000060.pdf: 947597 bytes, checksum: 96dfa3376ad9d96b655dea08792b363c (MD5)en
dc.description.provenanceMade available in DSpace on 2020-07-22T17:42:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2016en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/345933-
dc.description.conferencenomeConference on Clemson-University Power Systems (PSC)pt_BR
dc.contributor.departmentsem informaçãopt_BR
dc.contributor.departmentsem informaçãopt_BR
dc.contributor.unidadeFaculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.contributor.unidadeFaculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.subject.keywordActive filterspt_BR
dc.subject.keywordPower filterspt_BR
dc.subject.keywordPower qualitypt_BR
dc.identifier.source000380065000060pt_BR
dc.creator.orcid0000-0002-5406-3811pt_BR
dc.creator.orcid0000-0001-5457-4438pt_BR
dc.type.formArtigo de eventopt_BR
Appears in Collections:FEEC - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
000380065000060.pdf925.39 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.