Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/345116
Type: DISSERTAÇÃO DIGITAL
Degree Level: Mestrado
Title: O efeito do LED violeta e plasma de argônio no clareamento dental de consultório : The effect of violet LED and argon plasma on in-office tooth bleaching
Title Alternative: The effect of violet LED and argon plasma on in-office tooth bleaching
Author: Kury-Rodrigues, Matheus, 1991-
Advisor: Cavalli, Vanessa, 1977-
Abstract: Resumo: O objetivo deste trabalho foi avaliar o efeito do LED violeta (LED) e plasma de argônio (NATP), associados ou não ao peróxido de hidrogênio 35% (HP) e carbamida 37% (CP), no clareamento dental de consultório. No primeiro estudo, 90 coroas bovinas, pigmentadas com chá preto, foram submetidas aos tratamentos (n=10): LED, LED/HP, LED/CP, NATP, NATP/PH, NATP/CP, HP, CP e controle (C). LED foi irradiado vinte vezes por 1min com intervalos consecutivos de 30s (10 sessões) e NTAP foi aplicado por 10min (6 sessões). HP e CP foram aplicados por 30min (3 sessões). Quando associados a HP e CP, LED foi irradiado durante toda aplicação dos géis e NTAP foi aplicado nos 10min finais. Os espécimes foram mantidos em saliva artificial entre sessões e C permaneceu em saliva... O resumo poderá ser visualizado no texto completo da tese digital

Abstract: The objective of this study was to evaluate the effect of LED and NATP associated or not with 35% hydrogen peroxide (HP) and 37% carbamide peroxide (CP). Firstly, 90 incisor bovine crowns stained with black tea were submitted to the following treatments (n=10): LED, LED/HP, LED/CP, NATP, NATP/PH, NATP /CP, HP, CP and C - control. LED was irradiated twenty times for 1 min with consecutive 1-min intervals (10 sessions) and NTAP was applied for 10 minutes (6 sessions). HP and CP were applied for 30 min (3 sessions). When associated to HP and CP, LED was irradiated during all gel application and NTAP for the last 10 minutes of gel exposure. Specimens were maintained in artificial saliva (AS) among intervals and C was stored in AS throughout the experiment. L*a*b* values were obtained by means of spectrophotometry after staning (T0), last bleaching session (Tb) and 14 days... The abstract is available with the full electronic document
Subject: Dentes - Clareamento
Diodos emissores de luz
Peróxido de hidrogênio
Language: Inglês
Editor: [s.n.]
Citation: KURY-RODRIGUES, Matheus. O efeito do LED violeta e plasma de argônio no clareamento dental de consultório: The effect of violet LED and argon plasma on in-office tooth bleaching. 2019. 1 recurso online (76 p.) Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: http://www.repositorio.unicamp.br/handle/REPOSIP/345116. Acesso em: 10 Jul. 2020.
Date Issue: 2019
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
Kury-Rodrigues_Matheus_M.pdf8.38 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.