Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/342968
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.contributor.authorunicampCastilho, Lilian Maria de-
dc.typeArtigopt_BR
dc.titleRaro anticorpo associado à reação transfusional hemolítica grave : a importância de sua identificação para encontrar uma unidade sanguínea compatívelpt_BR
dc.title.alternativeThe rare holley antibody associated with a severe hemolytic transfusion reaction : the importance of this antibody identification to find a compatible blood unitpt_BR
dc.contributor.authorSantos, Leandro Dinalli-
dc.contributor.authorBub, Carolina Bonet-
dc.contributor.authorAravechia, Maria Giselda-
dc.contributor.authorBastos, Eduardo Peres-
dc.contributor.authorKutner, Jose Mauro-
dc.contributor.authorCastilho, Lilian-
dc.subjectImunoglobulinaspt_BR
dc.subjectSanguept_BR
dc.subjectTransfusão de sanguept_BR
dc.subject.otherlanguageImmunoglobulinspt_BR
dc.subject.otherlanguageBloodpt_BR
dc.subject.otherlanguageBlood transfusionpt_BR
dc.description.abstractA correta identificação dos anticorpos eritrocitários é fundamental na busca de sangue compatível e na prevenção das reações transfusionais hemolíticas. Anticorpos contra antígenos de alta prevalência são de difícil identificação, devido à raridade de sua ocorrência e à indisponibilidade de hemácias negativas para sua confirmação. Apresentamos aqui o caso de uma paciente do sexo feminino, 46 anos, com diagnóstico de hemoglobinopatia, que apresentou queda sintomática dos níveis de hemoglobina (5,3g/dL) após transfusão sanguínea, sugestiva de reação transfusional. O tipo sanguíneo da paciente era O RhD-positivo. A pesquisa de anticorpos irregulares foi positiva, demonstrando panreação contra todos os eritrócitos testados, mas não reativo ao ditiotreitol. Utilizando hemácias selecionadas negativas para antígenos de alta prevalência do nosso inventário, foi possível identificar no soro da mesma um anticorpo anti-Holley associado a um anti-E. A análise molecular confirmou que a paciente era negativa para os antígenos E e Holley, e as provas de compatibilidade com unidades fenotipadas confirmaram os resultados. Holley é um antígeno de alta prevalência do sistema sanguíneo Dombrock, cujo fenótipo negativo é extremamente raro em todas as populações e está associado a reações transfusionais hemolíticas. Trata-se de anticorpo de difícil identificação, pois os laboratórios precisam ter experiência na resolução de casos complexos, grande estoque de soros e eritrócitos raros, além de outras ferramentas, como enzimas, reagentes tiol e testes moleculares. A identificação correta de um anticorpo raro é inicial e obrigatória para a busca de doadores compatíveis, garantindo um suporte transfusional satisfatóriopt_BR
dc.relation.ispartofEinsteinpt_BR
dc.relation.ispartofabbreviationEinsteinpt_BR
dc.publisher.cityMorumbi, SPpt_BR
dc.publisher.countryBrasilpt_BR
dc.publisherSociedade Beneficente Israelita Brasileira Hospital Albert Einsteinpt_BR
dc.date.issued2020-
dc.language.isoporpt_BR
dc.description.volume18pt_BR
dc.rightsAbertopt_BR
dc.sourceSCIELOpt_BR
dc.identifier.issn1679-4508pt_BR
dc.identifier.eissn2317-6385pt_BR
dc.identifier.doi10.31744/einstein_journal/2020RC4582pt_BR
dc.identifier.urlhttps://www.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082020000100500pt_BR
dc.date.available2020-06-09T13:03:23Z-
dc.date.accessioned2020-06-09T13:03:23Z-
dc.description.provenanceSubmitted by Susilene Barbosa da Silva (susilene@unicamp.br) on 2020-06-09T13:03:23Z No. of bitstreams: 0. Added 1 bitstream(s) on 2020-09-03T11:56:03Z : No. of bitstreams: 1 S1679-45082020000100500por.pdf: 253560 bytes, checksum: d2a8a6a029d574e210e8a3d3641e7ee7 (MD5). Added 1 bitstream(s) on 2020-09-03T11:56:03Z : No. of bitstreams: 2 S1679-45082020000100500por.pdf: 253560 bytes, checksum: d2a8a6a029d574e210e8a3d3641e7ee7 (MD5) S1679-45082020000100500eng.pdf: 240959 bytes, checksum: bbe23d2294bd451f1ceb977378a2a186 (MD5)en
dc.description.provenanceMade available in DSpace on 2020-06-09T13:03:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2020en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/342968-
dc.contributor.departmentSem informaçãopt_BR
dc.contributor.unidadeCentro de Hematologia e Hemoterapiapt_BR
dc.description.abstractalternativeThe correct identification of erythrocyte antibodies is fundamental for the searching for compatible blood and haemolytic transfusion reactions prevention. Antibodies against antigens of high prevalence are difficult to identify because of the rarity of their occurrence and unavailability of negative red cells for confirmation. We report a case of 46-years-old woman, diagnosed with hemoglobinopathy, and who had symptomatic fall in hemoglobin levels (5.3g/dL) after blood transfusion suggestive of transfusion reaction. The patient’s blood type was O RhD-positive. Irregular antibody screening was positive and demonstrated a panreaction against all erythrocytes tested, but this result was not reactive with dithiothreitol. Using negative red cells for antigens of high prevalence of our inventory we could identify in the serum of the same erythrocytes an anti-Holley antibody associated with anti-E. Molecular analysis confirmed that the patient was negative for E and Holley antigens. The crossmath with compatible units confirmed the results. Holley is a high prevalence antigen of the Dombrock blood system whose negative phenotype is extremely rare in all populations and is associated with hemolytic transfusion reactions. This is an antibody that is difficult to identify because laboratories need to have experience in solving complex cases, and have available a large stock of rare sera and erythrocytes, as well other tools such as enzymes, thiol reagents and molecular tests. The correct identification of a rare antibody is initial and mandatory for searching of compatible donors, and to guarantee a satisfactory transfusional supportpt_BR
dc.subject.keywordReação transfusionalpt_BR
dc.identifier.sourceS1679-45082020000100500pt_BR
dc.creator.orcid0000-0002-3104-647Xpt_BR
dc.type.formCasopt_BR
Appears in Collections:HEMO - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
S1679-45082020000100500por.pdf247.62 kBAdobe PDFView/Open
S1679-45082020000100500eng.pdf235.31 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.