Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/342954
Type: Artigo
Title: Modelo de tubo endotraqueal de tamanho único para adultos
Title Alternative: Model of single-sized endotracheal tube for adults
Author: Calderon, Luiz Guilherme
Moreira, Marcos Mello
Barreto, Gilson
Tincani, Alfio José
Abstract: Simular diferentes diâmetros de tubos endotraqueais e verificar os aspectos fluidinâmicos, considerando medições de fluxo e resistência. Foi utilizado um software de fluidinâmica para calcular o fluxo médio e a resistência das vias aéreas nos tubos endotraqueais com diâmetro de 6,0, 7,0, 7,5, 8,0, 9,0 e 10,0mm, em temperatura corporal normal e pressão constante. As mesmas medidas foram realizadas na fusão dos primeiros 22cm de um tubo endotraqueal de 9,0 e 10,0mm de diâmetro, com a parte terminal em 12cm de um tubo endotraqueal de 6,0 e 7,0mm de diâmetro. A fusão dos primeiros 22cm de um tubo endotraqueal de diâmetro 10,0 mm com a parte terminal em 12cm de um tubo endotraqueal de 6,0mm de diâmetro, preservando o comprimento total de 34cm, gerou fluxo médio e resistência de vias aéreas semelhantes aos de um tubo endotraqueal convencional de 7,5mm. Um tubo endotraqueal de tamanho único pode facilitar a intubação endotraqueal, sem causar aumento de resistência na via aérea
metadata.dc.description.abstractalternative: To simulate different diameters of endotracheal tubes and to verify the fluid dynamics aspects by means of flow and resistance measurements. Fluid dynamics software was used to calculate mean flow and airway resistance in endotracheal tube with a diameter of 6.0, 7.0, 7.5, 8.0, 9.0 and 10.0mm at normal body temperature and under constant pressure. The same measurements were taken in the fusion of the first 22cm of a 9.0mm endotracheal tube with 10.0mm diameter, and with the end part in 12cm of a 6.0mm endotracheal tube with 7.0mm diameter. The fusion of the first 22cm of an endotracheal tube of 10.0mm diameter with the terminal part in 12cm of an endotracheal tube of 6.0mm diameter, preserving the total length of 34cm, generated average flow and airway resistance similar to that of a conventional 7.5mm endotracheal tube. This simulation study demonstrates that a single-sized endotracheal tube may facilitate endotracheal intubation without causing increased airway resistance.
Subject: Intubação intratraqueal
Country: Brasil
Editor: Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein
Rights: Aberto
Identifier DOI: 10.31744/einstein_journal/2020AO4805
Address: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082020000100204
Date Issue: 2019
Appears in Collections:FCM - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
S1679-45082020000100204eng.pdf282.86 kBAdobe PDFView/Open
S1679-45082020000100204por.pdf296.71 kBAdobe PDFView/Open