Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/342437
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.contributor.authorunicampAlmeida, Beatriz Pera de-
dc.contributor.authorunicampAlvares, Beatriz Regina-
dc.contributor.authorunicampJales, Rodrigo Menezes-
dc.contributor.authorunicampCaldas, Jamil Pedro de Siqueira-
dc.contributor.authorunicampCarmona, Elenice Valentim-
dc.typeArtigopt_BR
dc.titleUse of pH reagent strips to verify gastric tube placement in newbornspt_BR
dc.contributor.authorDias, Flávia de Souza Barbosa-
dc.contributor.authorAlmeida, Beatriz Pera de-
dc.contributor.authorAlvares, Beatriz Regina-
dc.contributor.authorJales, Rodrigo Menezes-
dc.contributor.authorCaldas, Jamil Pedro de Siqueira-
dc.contributor.authorCarmona, Elenice Valentim-
dc.subjectSuco gástricopt_BR
dc.subject.otherlanguageGastric juicept_BR
dc.description.abstractTo confirm the accuracy of the pH test in identifying the placement of the gastric tube in newborns. METHOD: double-blind, diagnostic test study conducted with 162 newborns admitted to a neonatal intensive care unit and an intermediate care unit. The subjects were submitted to enteral intubation, followed by pH test with reagent strip, which was analyzed by a nurse, and radiological examination, analyzed by radiologist. Blinding was kept among professionals regarding test results. Diagnostic accuracy analysis of the pH test in relation to the radiological exam was performed. RESULTS: the sample consisted of 56.17% boys, with average birth weight of 1,886.79g (SD 743,41), 32.92 (SD 2.99) weeks of gestational age and the mean pH was 3.36 (SD 1.27). Considering the cutoff point of pH≤5.5, the sensitivity was 96.25%, specificity 50%, positive predictive value 99.35% and negative predictive value 14.29%. CONCLUSION: The pH test performed with reagent strips is sensitive to identify the correct placement of the gastric tube, so it can be used as an adjuvant technique in the evaluation of the gastric tube placement. In interpreting the results, pH ≤5.5 points to correct placement and values > 5.5 require radiological confirmationpt_BR
dc.relation.ispartofRevista latino-americana de enfermagempt_BR
dc.relation.ispartofabbreviationRev. lat. am. enfermagempt_BR
dc.publisher.cityRibeirão Preto, SPpt_BR
dc.publisher.countryBrasilpt_BR
dc.publisherUSP/Escola de Enfermagem de Ribeirão Pretopt_BR
dc.date.issued2019-
dc.date.monthofcirculationDec.pt_BR
dc.language.isoengpt_BR
dc.description.volume27pt_BR
dc.rightsAbertopt_BR
dc.sourceScopuspt_BR
dc.identifier.issn0104-1169pt_BR
dc.identifier.eissn1518-8345pt_BR
dc.identifier.doi10.1590/1518-8345.3150.3227pt_BR
dc.identifier.urlhttps://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-11692019000100407pt_BR
dc.date.available2020-06-02T14:44:00Z-
dc.date.accessioned2020-06-02T14:44:00Z-
dc.description.provenanceSubmitted by Thais de Brito Barroso (tbrito@unicamp.br) on 2020-06-02T14:44:00Z No. of bitstreams: 0. Added 1 bitstream(s) on 2020-09-03T11:55:25Z : No. of bitstreams: 1 2-s2.0-85076410723.pdf: 1069524 bytes, checksum: 6976003b47620da921db4eb9e85ee4dc (MD5)en
dc.description.provenanceMade available in DSpace on 2020-06-02T14:44:00Z (GMT). No. of bitstreams: 0 Previous issue date: 2019en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/342437-
dc.contributor.departmentSem informaçãopt_BR
dc.contributor.departmentDepartamento de Radiologiapt_BR
dc.contributor.departmentDepartamento de Tocoginecologiapt_BR
dc.contributor.departmentDepartamento de Pediatriapt_BR
dc.contributor.departmentSem informaçãopt_BR
dc.contributor.unidadeCentro de Atenção Integral à Saúde da Mulherpt_BR
dc.contributor.unidadeFaculdade de Ciências Médicaspt_BR
dc.contributor.unidadeFaculdade de Ciências Médicaspt_BR
dc.contributor.unidadeFaculdade de Ciências Médicaspt_BR
dc.contributor.unidadeFaculdade de Enfermagempt_BR
dc.subject.keywordIntubationpt_BR
dc.subject.keywordGastrointestinalpt_BR
dc.subject.keywordEnteral nutritionpt_BR
dc.subject.keywordInfantpt_BR
dc.subject.keywordNewbornpt_BR
dc.subject.keywordHydrogen-ion concentrationpt_BR
dc.subject.keywordNeonatal nursingpt_BR
dc.identifier.source2-s2.0-85076410723pt_BR
dc.creator.orcid0000-0002-3766-8165pt_BR
dc.creator.orcid0000-0002-0181-3885pt_BR
dc.creator.orcid0000-0002-8802-8870pt_BR
dc.creator.orcid0000-0001-5292-2320pt_BR
dc.creator.orcid0000-0001-9976-3603pt_BR
dc.type.formArtigo originalpt_BR
dc.identifier.articleide3227pt_BR
Appears in Collections:FCM - Artigos e Outros Documentos
CAISM - Artigos e Outros Documentos
FENF - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
2-s2.0-85076410723.pdf1.04 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.