Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/342272
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.identifier.isbn978-1-5386-7995-1pt_BR
dc.contributor.authorunicampMesquita, Daniel de Bastos-
dc.contributor.authorunicampSilva, João Lucas de Souza-
dc.contributor.authorunicampMoreira, Hugo Soeiro-
dc.contributor.authorunicampVillalva, Marcelo Gradella-
dc.typeArtigopt_BR
dc.titleResidual voltage tests in zinc oxide (ZnO) surge arrester of 69kVpt_BR
dc.contributor.authorMesquita, Daniel de Bastos-
dc.contributor.authorSilva, João Lucas de Souza-
dc.contributor.authorMoreira, Hugo Soeiro-
dc.contributor.authorVillalva, Marcelo Gradella-
dc.subjectPára-raiospt_BR
dc.subjectÓxido de zincopt_BR
dc.subject.otherlanguageLightning conductorspt_BR
dc.subject.otherlanguageZinc oxidept_BR
dc.description.abstractEquipment such as surge arresters are subject to various setbacks due to their exposure to adverse weather conditions. As a consequence of these setbacks, leaks of currents towards the ground can occur and cause accidents. In this way, high voltage tests are important to ensure the reliability of the equipment in the electrical system. As a benchmark for testing, IEC 60099-4 establishes the minimum reliability criteria for the operation of the surge arrester. In this context, the objective of this work is to perform Residual Voltage Tests in Zinc Oxide (ZnO) Surge Arrester of 69 kV and to compare the results with the data provided by the manufacturer which are based on the minimum criteria of IEC 60099-4. The methodology to obtain the results consisted in the measurement of residual voltage in the ZnO surge arrester the 69 kV for a current discharge of 5 kA and 10 kA using a Current Impulse Generator based on a Voltage Atmospheric Voltage Generator model SGD and reference data supplied by the manufacturer as well as the IEC 60099-4 standard. The measured residual voltage values were higher than the values guaranteed by the manufacturer according to the reference data. According to IEC 60099-4, the surge arrester can not be considered reliable and therefore is not capable of operatingpt_BR
dc.relation.ispartofIEEE industry applications magazinept_BR
dc.publisher.cityPiscataway, NJpt_BR
dc.publisher.countryEstados Unidospt_BR
dc.publisherInstitute of Electrical and Electronics Engineerspt_BR
dc.date.issued2019-
dc.date.monthofcirculationJan.pt_BR
dc.language.isoengpt_BR
dc.rightsFechadopt_BR
dc.sourceSCOPUSpt_BR
dc.identifier.issn1077-2618pt_BR
dc.identifier.eissn1558-0598pt_BR
dc.identifier.doi10.1109/INDUSCON.2018.8627319pt_BR
dc.identifier.urlhttps://ieeexplore.ieee.org/document/8627319pt_BR
dc.description.sponsorshipCONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQpt_BR
dc.description.sponsorshipCOORDENAÇÃO DE APERFEIÇOAMENTO DE PESSOAL DE NÍVEL SUPERIOR - CAPESpt_BR
dc.description.sponsorshipFUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESPpt_BR
dc.description.sponsordocumentnumber2016/08645-9pt_BR
dc.date.available2020-05-29T17:58:40Z-
dc.date.accessioned2020-05-29T17:58:40Z-
dc.description.provenanceSubmitted by Susilene Barbosa da Silva (susilene@unicamp.br) on 2020-05-29T17:58:40Z No. of bitstreams: 0. Added 1 bitstream(s) on 2020-08-27T19:17:52Z : No. of bitstreams: 1 2-s2.0-85062573046.pdf: 366063 bytes, checksum: 84eae6ad7f96f572dcd839146e67a741 (MD5)en
dc.description.provenanceMade available in DSpace on 2020-05-29T17:58:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2019en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/342272-
dc.description.conferencenome13th IEEE International conference on industry applications (INDUSCON)pt_BR
dc.contributor.departmentSem informaçãopt_BR
dc.contributor.departmentSem informaçãopt_BR
dc.contributor.departmentSem informaçãopt_BR
dc.contributor.departmentDepartamento de Sistemas e Energiapt_BR
dc.contributor.unidadeFaculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.contributor.unidadeFaculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.contributor.unidadeFaculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.contributor.unidadeFaculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.subject.keywordElectric surgespt_BR
dc.subject.keywordII-VI semiconductorspt_BR
dc.subject.keywordManufacturept_BR
dc.subject.keywordElectrical systemspt_BR
dc.identifier.source2-s2.0-85062573046pt_BR
dc.creator.orcidSem informaçãopt_BR
dc.creator.orcid0000-0003-3206-2241pt_BR
dc.creator.orcid0000-0002-8007-2834pt_BR
dc.creator.orcid0000-0003-1654-2173pt_BR
dc.type.formArtigo de eventopt_BR
dc.identifier.articleid18438104pt_BR
dc.description.sponsorNoteThis work was supported by the agencies CNPq, CAPES and FAPESP (2016/08645-9), ANEEL (CPFL-PA3032) and BYD ENERGY through the PADIS programpt_BR
Appears in Collections:FEEC - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
2-s2.0-85062573046.pdf357.48 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.