Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/341548
Type: TESE DIGITAL
Degree Level: Doutorado
Title: Janela ventilada de vidro duplo com e sem película refletiva
Title Alternative: Ventilated double glass window without/with reflective film
Author: Lago, Taynara Geysa Silva do, 1991-
Advisor: Ismail, Kamal Abdel Radi, 1940-
Abstract: Resumo: O presente trabalho aponta um estudo sobre desempenho térmico de uma janela ventilada de vidro duplo com e sem película refletiva sob condições climáticas quentes e frias da cidade de Campinas. A janela é composta de duas placas de vidro separadas por um espaço entre elas formando um canal. Inicialmente, foi estudada a janela ventilada sem película refletiva, e logo depois foi estudada a aplicação de película nos vidros. O vidro-1 é voltado para o ambiente externo e o vidro-2 voltado para o ambiente interno. Uma película refletiva solar é fixada na superfície interna do vidro-1 para condições de clima quente, ou fixada na superfície interna do vidro-2 para condições de clima frio. Um código numérico foi construído e desenvolvido, usando o Método do Volume Finito (MVF) para discretização das equações de conservação. Considera-se a transferência de calor por condução através das placas de vidro, o mecanismo convectivo do ar contido na cavidade sob regime de fluxo laminar, assim como a troca radiativa entre as paredes. O modelo de convecção natural foi utilizado para as equações governantes do fluido newtoniano em regime de escoamento laminar. A equação de energia com difusão pura foi resolvida para a transferência de calor por condução nas paredes verticais. A troca radiativa entre as paredes foi resolvida pelo Método de Radiação Líquida (MRN). O programa é validado com resultados numéricos e experimentais disponíveis na literatura e as simulações foram feitas para cada hora de um dia representativo. Três possibilidades foram definidas para avaliar o sistema: 1-Janela ventilada de vidro duplo sem película refletiva; 2- Janela ventilada de vidro duplo com película refletiva para condição de clima quente; 3- Janela ventilada de vidro duplo com película refletiva para condição de clima frio. Conclui-se que o espaçamento ótimo para a abertura formada entre as duas folhas de vidro é b ? 3 cm e é conveniente usar o conceito proposto de janela reversível com uma película refletiva, porque para o tempo quente funcionaria perfeitamente e no tempo frio o comportamento térmico é 12% menor do que a janela sem uma película refletiva

Abstract: The present work points to a study on the thermal performance of a ventilated double glass window with and without reflective film under hot and cold climatic conditions in the city of Campinas. The window is composed of two glass plates separated by a space between them forming a channel. Initially, the ventilated window without reflective film was studied, and soon afterwards, the application of film on the glasses was studied. Glass-1 is facing the external environment and glass-2 is facing the internal environment. A reflective solar film is attached to the inner surface of glass-1 for hot weather conditions, or attached to the inner surface of glass-2 for cold weather conditions. A numerical code was built and developed, using the Finite Volume Method (MVF) to discretize conservation equations. It is considered the transfer of heat by conduction through the glass plates, the convective mechanism of the air contained in the cavity under laminar flow regime, as well as the radiative exchange between the walls. The natural convection model was used for the governing equations of the Newtonian fluid in a laminar flow regime. The energy equation with pure diffusion was solved for the transfer of heat by conduction in the vertical walls. The radiative exchange between the walls was resolved by the Liquid Radiation Method (MRN). The program is validated with numerical and experimental results available in the literature and the simulations were carried out for each hour of a representative day. Three possibilities were defined to evaluate the system: 1-Double-glass ventilated window without reflective film; 2- Ventilated double glass window with reflective film for hot weather condition; 3- Ventilated double glass window with reflective film for cold weather conditions. It is concluded that the optimal spacing for the opening formed between the two glass sheets is b ? 3 cm and it is convenient to use the proposed concept of a reversible window with a reflective film, because for hot weather it would work perfectly and in cold weather the behavior thermal is 12% smaller than the window without a reflective film
Subject: Janelas
Radiação solar
Peliculas - Filmes
Análise numérica
Conforto térmico
Language: Português
Editor: [s.n.]
Citation: LAGO, Taynara Geysa Silva do. Janela ventilada de vidro duplo com e sem película refletiva. 2020. 1 recurso online (191 p.) Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica, Campinas, SP.
Date Issue: 2020
Appears in Collections:FEM - Tese e Dissertação

Files in This Item:
File SizeFormat 
Lago_TaynaraGeysaSilvaDo_D.pdf4.34 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.