Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/340753
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.contributor.authorunicampMouraria, Guilherme Grisi-
dc.contributor.authorunicampZoppi Filho, Américo-
dc.contributor.authorunicampMoratelli, Lucas-
dc.contributor.authorunicampCruz, Marcio Alves-
dc.contributor.authorunicampEtchebehere, Maurício-
dc.typeArtigopt_BR
dc.titleProximal humeral fractures treated with osteosynthesis using the anterolateral approachpt_BR
dc.title.alternativeFratura do úmero proximal tratadas com osteossíntese pela via de acesso anterolateralpt_BR
dc.contributor.authorMouraria, Guilherme Grisi-
dc.contributor.authorZoppi Filho, Americo-
dc.contributor.authorKikuta, Fernando Kenji-
dc.contributor.authorMoratelli, Lucas-
dc.contributor.authorSilveira Junior, Paulo Pedroso-
dc.contributor.authorEtchebehere, Mauricio-
dc.subjectFraturas do úmeropt_BR
dc.subject.otherlanguageHumeral fracturespt_BR
dc.description.abstractThe main surgical approach in proximal humeral fractures is the deltopectoral approach. Many surgeons avoid the anterolateral approach, fearing its complications, especially axillary nerve injury. The objective of this study is to evaluate shoulder function and complications in patients with proximal humeral fractures treated using an anterolateral approach with direct observation of the axillary nerve. Methods: Retrospective study with postoperative radiological and functional evaluations (Constant and DASH scores) and review of the complications. The associations between fracture classification and the difference in Constant scores among the subjects and the final angle of consolidation were analyzed using Fisher's test or analysis of variance (ANOVA). The Constant scores were compared among the shoulders using the paired t-test. Results: The study evaluated 35 patients. Shoulder function was decreased, compared with the contralateral side (p <0.005). The only factor related to functional worsening was the Neer IV fracture. The main complication was malunion. There were no clinical changes related to the axillary nerve. Conclusion: The treatment using the extended anterolateral approach produced good functional results, although the function was decreased (Neer IV fractures). The main complication was malunion. There were no side effects due to exposure of the axillary nervept_BR
dc.relation.ispartofActa ortopedica brasileirapt_BR
dc.relation.ispartofabbreviationActa ortop. bras.pt_BR
dc.publisher.citySão Paulo, SPpt_BR
dc.publisher.countryBrasilpt_BR
dc.publisherUSP/Faculdade de Medicinapt_BR
dc.date.issued2019-
dc.date.monthofcirculationMay/Junept_BR
dc.language.isoengpt_BR
dc.description.volume27pt_BR
dc.description.issuenumber3pt_BR
dc.description.firstpage173pt_BR
dc.description.lastpage177pt_BR
dc.rightsAbertopt_BR
dc.sourceWOSpt_BR
dc.identifier.issn1413-7852pt_BR
dc.identifier.eissn1809-4406pt_BR
dc.identifier.doi10.1590/1413-785220192703218226pt_BR
dc.identifier.urlhttps://www.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522019000300173pt_BR
dc.description.sponsordocumentnumbersem informaçãopt_BR
dc.date.available2020-05-12T22:58:21Z-
dc.date.accessioned2020-05-12T22:58:21Z-
dc.description.provenanceSubmitted by Sanches Olivia (olivias@unicamp.br) on 2020-05-12T22:58:21Z No. of bitstreams: 0. Added 1 bitstream(s) on 2020-08-27T19:16:22Z : No. of bitstreams: 1 000469447800009.pdf: 1036008 bytes, checksum: 2986af3ed9929df5ebab423fcc852702 (MD5)en
dc.description.provenanceMade available in DSpace on 2020-05-12T22:58:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2019en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/340753-
dc.contributor.departmentsem informaçãopt_BR
dc.contributor.departmentsem informaçãopt_BR
dc.contributor.departmentsem informaçãopt_BR
dc.contributor.departmentsem informaçãopt_BR
dc.contributor.departmentDepartamento de Ortopedia e Traumatologiapt_BR
dc.contributor.unidadeFaculdade de Ciências Médicaspt_BR
dc.contributor.unidadeFaculdade de Ciências Médicaspt_BR
dc.contributor.unidadeFaculdade de Ciências Médicaspt_BR
dc.contributor.unidadeFaculdade de Ciências Médicaspt_BR
dc.contributor.unidadeFaculdade de Ciências Médicaspt_BR
dc.description.abstractalternativeA via de acesso mais utilizada na osteossíntese das fraturas de úmero proximal é a deltopeitoral. A via anterolateral sofre resistência, pois muitos temem suas complicações, principalmente lesão do nervo axilar. Objetivo é avaliar a função do ombro e as complicações nas fraturas de úmero proximal, tratados pela via anterolateral com observação direta do nervo axilar. Métodos: Estudo retrospectivo com avaliação radiológica e funcional (Constant e DASH scores) pós-operatórios e complicações. A associação entre a classificação da fratura e a diferença dos escores entre os membros, bem como o ângulo final de consolidação, foram analisados pelo Teste de Fisher ou Anova. A comparação dos escores Constant entre os membros foi conduzida pelo teste t pareado. Resultados: foram avaliados 35 pacientes. Houve diminuição da função do ombro em relação ao contralateral (p<0,005). O único fator relacionado à piora funcional foi fratura Neer IV. A principal complicação foi consolidação viciosa. Não se observou alterações clínicas relacionadas ao nervo axilar. Conclusão: A osteossíntese das fraturas do úmero proximal realizada pela via de acesso anterolateral estendida, apesar da diminuição da função do ombro (fraturas Neer IV), evoluiu com bom resultado funcional e mostrou-se segura na proteção do nervo axilar. Nível de evidência III, Estudo Retrospectivopt_BR
dc.subject.keywordSurgerypt_BR
dc.subject.keywordComplicationspt_BR
dc.subject.keywordOsteosynthesis fracturept_BR
dc.identifier.source000469447800009pt_BR
dc.creator.orcid0000-0002-8258-5350pt_BR
dc.creator.orcid0000-0002-8704-8378pt_BR
dc.creator.orcid0000-0002-6584-5333pt_BR
dc.creator.orcid0000-0001-9074-9186pt_BR
dc.creator.orcid0000-0002-5176-2369pt_BR
dc.type.formArtigo originalpt_BR
dc.description.otherSponsorshipsem informaçãopt_BR
Appears in Collections:FCM - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
000469447800009.pdf1.01 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.