Title: Avaliação in vitro da redução de Enterococcus faecalis dos canais radiculares utilizando um sistema de eletrofulguração
Title Alternative: In vitro evaluation of Enterococcus faecalis reduction of root canals using a electrofulguration system
Author: Brum, Cimara Barroso Braga, 1975-
Advisor: Gomes, Brenda Paula Figueiredo de Almeida
Abstract: Resumo: O objetivo deste estudo foi avaliar in vitro a capacidade de desinfecção de um aparelho de eletrofulguração, o sistema Endox® Endodontic System, em canais contaminados com Enterococcus faecalis, comparando sua eficácia com as substâncias químicas auxiliares (SQA) hipoclorito de sódio 5,25% (NaOCl) e clorexidina gel 2% (CHX). Foram utilizados 65 pré-molares inferiores humanos, unirradiculares e com ápices completamente formados. Os dentes foram padronizados quanto ao comprimento e formatação inicial do canal radicular para posterior contaminação por 21 dias com E. faecalis. Os espécimes foram divididos em 6 grupos experimentais (n=10) de acordo com o protocolo de desinfecção e a SQA utilizada durante o preparo químico-mecênico (PQM): Grupo CHX; Grupo CHX + aplicação de eletrofulguração (EX); Grupo NaOCl; Grupo NaOCl + EX; Grupo soro fisiológico (SF) + EX; como controle negativo foram utilizados 5 espécimes. Amostras do canal radicular foram coletadas inicialmente, após EX, após PQM e após EX final, a fim de se determinar as unidades formadoras de colônias (UFC/mL). A análise estatística foi realizada através dos testes de Wilcoxon e Friedman para comparações intragrupo e os testes Mann Whitney e Kruskal Wallis, complementado pelo teste de Dunn, para as comparações intergrupo (? = 0,05). Os grupos que receberam aplicação de EX antes do PQM, não apresentaram redução significativa da carga microbiana quando comparado com os valores iniciais (C1 ~ C2, p > 0,05). Após PQM, todos os grupos apresentaram uma redução significativa de UFC/mL (p < 0,05). Quando comparados os valores de UFC/mL após PQM (C3) entre os diferentes grupos, pode-se observar uma maior redução nos grupos onde foi utilizada CHX ou NaOCl como SQA em relação aos grupos controle (SF e Soro + EX). Os grupos que receberam EX após o PQM, não mostraram redução significativa da carga bacteriana (C3 ~ C4, p > 0,05). Concluiu-se que a utilização do Sistema Endox não influenciou numa maior redução da carga microbiana; adicionalmente, tanto NaOCl como CHX foram igualmente efetivas nessa redução

Abstract: The aim of this study was to evaluate in vitro capacity of disinfection of an eletrofulguration device, the Endox ® Endodontic System, in canals contaminated with Enterococcus faecalis, comparing its effectiveness with the chemical auxiliary substances 5.25% sodium hypochlorite and 2% chlorhexidine gel. For this purpose, 65 lower premolars human, with complete root formation were selected. Teeth were standardized for root canal length and initial preparation and subsequently infected for 21 days with E. faecalis. The specimens were divided into 6 experimental groups (n=10) according to disinfection protocol and substance used during chemomechanical preparation: CHX group; CHX group + eletrofulguration application (EX); NaOCl group; NaOCl + EX; Saline group; Saline + EX; As negative control 5 specimens were used. Root canals samples were collected after EX, after PQM and after final EX to determine the colony forming units (CFU/mL). Statistical analysis was performed using the Wilcoxon and Friedman tests for intragroup comparisons and the Mann Whitney and Kruskal Wallis tests, complemented by the Dunn test for intergroup comparisons (? = 0,05). The groups that received EX application before PQM did not present a significant reduction of the microbial load when compared to the initial values (C1 ~ C2, p > 0,05). After chemomechanical preparation all groups had a significant reduction of CFU/mL (p < 0,05). When comparing the values of CFU/ mL after PQM (C3) between the different groups, a greater reduction can be observed in groups where CHX or NaOCl was used as substances in relation to the control groups (SF and SF+EX). Groups that received EX after preparation did not show a significant reduction in bacterial load (C3 ~ C4, p > 0,05). It was concluded that the use of the Endox® System did not influence a greater reduction of the microbial load. In addition, both NaOCl and CHX were equally effective in this reduction
Subject: Preparo de canal radicular
Hipoclorito de sódio
Clorexidina
Irrigantes do canal radicular
Enterococcus faecalis
Editor: [s.n.]
Citation: BRUM, Cimara Barroso Braga. Avaliação in vitro da redução de Enterococcus faecalis dos canais radiculares utilizando um sistema de eletrofulguração. 2017. 1 recurso online (65 p.). Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP.
Date Issue: 2017