Title: Controle do nível de compatibilidade eletromagnética para gerenciamento de risco em estabelecimentos assistenciais de saúde
Title Alternative: Electromagnetic compatibility level control for risk management in healthcare facilities
Author: Evangelista, Jamilson Ramos, 1977-
Advisor: Muhlen, Sérgio Santos, 1956-
Abstract: Resumo: A área médica tem sido muito beneficiada com o uso de tecnologias eletrônicas, seja para monitoração, diagnóstico ou terapia dos pacientes. O avanço contínuo destas tecnologias inclui a observância de requisitos normativos e regulatórios (principalmente nos aspectos de segurança e desempenho essencial) de Equipamentos Eletromédicos (EEM). Fatores como o aumento do número de Estabelecimentos Assistenciais de Saúde (EAS) nos grandes centros, muitas vezes localizados próximos a estações de radiocomunicação, a implantação de sistemas de comunicação sem fio no interior dos EAS como parte da infraestrutura, a diversidade de gerações tecnológicas dos EEM, podem gerar uma condição de baixa Compatibilidade Eletromagnética (CEM) para os EEM. Esta condição pode afetar o desempenho dos EEM e consequentemente gerar um risco funcional, causando danos aos pacientes, comprometendo os usuários, a qualidade do serviço médico, a credibilidade do EAS ou mesmo dos fabricantes dos EEM. A partir desse contexto, ganha destaque o papel da Engenharia Clínica em gerenciar as tecnologias e, sobretudo o seus riscos. O conhecimento do contexto normativo da certificação e avaliação da imunidade eletromagnética de EEM, e as suas implicações no ciclo de vida dos produtos, a execução de atividades de análise, avaliação e controle tanto da imunidade dos EEM quanto das perturbações eletromagnéticas nos ambientes críticos dos EAS, viabiliza a utilização segura de EEM de diferentes tipos e gerações em conjunto com sistemas de comunicação sem fio localizados dentro e fora dos EAS¿s. Este trabalho tem como proposta apresentar um método de bases práticas para a manutenção do nível de compatibilidade eletromagnética pela engenharia clínica no gerenciamento de risco de tecnologias para o controle de Interferência Eletromagnética (EMI) na incorporação e manutenção de equipamentos e sistemas de comunicação sem fio. O método proposto apresenta as atividades a serem realizadas para controle das perturbações eletromagnéticas no ambiente de uso e atividades relacionadas a aquisição e manutenção dos EEM. As implementações propostas são demonstradas através de análise de documentos, inclusive normativos, avaliação de manual de equipamento, estimativas e cálculos teóricos, e a realização de medições em EEM e ambientes de uso. Por fim são propostas alternativas para adoção da metodologia considerando as limitações do trabalho, diversidade de ambientes e variedades de EEM. A aplicação dessa metodologia em outros cenários irão contribuir para a geração de informações para engenharia clínica em relação a gestão eletromagnética dos EAS¿s

Abstract: Medical healthcare has been greatly benefited by the use of electronic technologies, whether for monitoring, diagnosis or therapy of patients. The continuous advancement of these technologies includes compliance with standards and regulatory requirements (mainly in the safety aspects and essential performance) of Medical Electrical Equipment (MEE) and Medical Electrical Systems (MES). Factors such as the increase in the number of Healthcare Establishments (HE) in large centers, often located near radio communication stations, the deployment of wireless communication systems within the HE as part of the infrastructure, the diversity of MME, can generate a condition of low electromagnetic compatibility. This condition can compromise the performance of the MME and consequently generate a functional risk, affecting users and patients, jeopardizing the quality of the medical service, the credibility of the HE or even the MME manufacturer. In this scenario, the role of clinical engineering in managing technologies and, above all, their risks, is highlighted. Knowledge of the normative context of the certification and evaluation of electromagnetic immunity of MME and their implications in the equipment life cycle, the performance of analysis, evaluation and control activities of MME immunity and electromagnetic disturbances in critical environments of HE, enables the safe use of MME of different types and generations in conjunction with wireless communication systems located inside and outside the HE. This study proposes to be a practical method of bases for the maintenance of the level of electromagnetic compatibility by clinical engineering in the risk management of technologies for the control of Electromagnetic Interference (EMI) in the incorporation and maintenance of wireless communication equipment and systems. The proposed implementation are showed based on documents analyses, including standards, user manual evaluation, estimation and theory calculus and measurement performance on equipment and use environment. Finally are proposing alternatives for application of methodology considering the limitation of this study, environment diversity and MME variety. The methodology application in other scenarios will to contribute in information database for Clinical Engineering regarding the Electromagnetic Management of HE
Subject: Equipamentos médico
Engenharia biomédica
Engenharia biomedica - Equipamento e acessórios
Administração de risco
Compatilidade eletromagnética
Language: Português
Editor: [s.n.]
Citation: EVANGELISTA, Jamilson Ramos. Controle do nível de compatibilidade eletromagnética para gerenciamento de risco em estabelecimentos assistenciais de saúde. 2018. 1 recurso online (94 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/331520>. Acesso em: 3 set. 2018.
Date Issue: 2018