Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/331462
Type: DISSERTAÇÃO DIGITAL
Degree Level: Mestrado
Title: Alvenaria estrutural em situação de incêndio : proposta de avaliação com vistas à normatização
Title Alternative: Structural masonry submitted to fire : an evaluation proposition aiming towards standardization
Author: Leite, Helena Arias Lara, 1990-
Advisor: Moreno Junior, Armando Lopes, 1964-
Abstract: Resumo: O Brasil carece de uma legislação sobre alvenaria estrutural em situação de incêndio. Por conta disso, o Corpo de Bombeiros do Estado de São Paulo (2011) recomenda que se faça esse dimensionamento de acordo com as recomendações do Eurocode 6 (2005) ou norma internacional similar. Com o intuito de subsidiar futuras discussões sobre uma normatização nacional, neste trabalho são apresentados os procedimentos de dimensionamento da alvenaria estrutural em situação de incêndio em vigor na África do Sul, nos Estados Unidos, na Austrália, na Nova Zelândia e na Europa. Também são apresentados os principais parâmetros envolvidos na resistência ao fogo de paredes de alvenaria estrutural de blocos de concreto. Uma simulação numérica preliminar foi feita para verificar a influência do tipo de agregado na resistência ao fogo pelo critério de isolamento térmico de um bloco de concreto; e constatou-se que, aparentemente, por alterar a condutividade térmica do bloco, o tipo de agregado influencia sim na resistência ao fogo do mesmo. Ao final, sem deixar ao largo o questionamento da aplicabilidade dessas cinco normas à situação brasileira, por conta das diferenças de materiais utilizados tanto nos blocos quanto nos acabamentos, sugere-se mesclar o que há de interessante nesses códigos internacionais, de forma gradativa, na elaboração de futura norma brasileira sobre o assunto

Abstract: In Brazil, there is no standard regarding the design of masonry walls in fire situations. According to the Fire Department of São Paulo State (2011), either the Eurocode 6 (2005) or an equally recognized international Standard should be used in such a situation. In this work, design specifications for masonry walls in situation of fire are presented, according to the standard requirements in South Africa, in the United States of America, in Australia, in New Zealand and in Europe. The main parameters involved in masonry walls¿ fire resistance are also presented. A simulation of a concrete unit with three different aggregate types was made in order to check if the aggregate type has any sort of influence in the fire resistance of the unit, considering the insulation criterion; and it was observed that because it alters the thermal conductivity of the unit, apparently the aggregate type has an influence in its fire resistance. One might question the applicability of these codes in the Brazilian context, due to the different materials the structural units are made of and the rendering applied on the walls. Taking that into account, we suggest that the applicable elements of these international standards should be gradually integrated into the development of a Brazilian standard
Subject: Alvenaria estrutural
Incêndios
Language: Português
Editor: [s.n.]
Citation: LEITE, Helena Arias Lara. Alvenaria estrutural em situação de incêndio: proposta de avaliação com vistas à normatização. 2018. 1 recurso online (152 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/331462>. Acesso em: 3 set. 2018.
Date Issue: 2018
Appears in Collections:FEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
Leite_HelenaAriasLara_M.pdf3.66 MBAdobe PDFView/Open