Title: Avaliação do desempenho de um sistema de refrigeração devido a substituição do fluido refrigerante
Title Alternative: Evaluation of the performance of a refrigeration system due to the replacement of the refrigerant
Author: Cutrim, Yuri Alisson Barreto, 1990-
Advisor: Moura, Luiz Felipe Mendes de, 1958-
Abstract: Resumo: Devido as preocupações ambientais e influência dos fluidos refrigerantes no agravamento da destruição da camada de ozônio e do aquecimento global, uma série de estudos tem sido realizados na busca de soluções viáveis para tais mazelas. Mediante a isso, este trabalho tem objetivo de analisar o desempenho do hidrocarboneto (HC) R600a em substituição ao hidrofluorcarboneto (HFC) R134a. Para os experimentos, foi utilizado uma bancada experimental de sistema de refrigeração por compressão de vapor, na qual simula um condicionador de ar. Para análise dos desempenhos, foram utilizadas equações matemáticas baseadas na primeira lei da termodinâmica e, ainda, foi dado enfoque a parâmetros como pressão de condensação e evaporação, vazão mássica do fluido refrigerante, cargas térmicas do evaporador, potência consumida pelo compressor e, por fim, o coeficiente de performance (COP) do sistema. A análise dos resultados demonstra que, para uma mesma carga térmica, o R600a apresentou eficiência energética de 9\% a 11\% inferior ao R134a. No entanto, investigando a influência da rotação do compressor para cada fluido, concluiu-se que a substituição é viável mediante aplicações de cargas térmicas mais baixas, uma vez que o R600a apresenta COP de até 36\% superior em comparação ao R134a

Abstract: Due to environmental concerns and influence of refrigerant fluids in worsening ozone depletion and global warming, a number of studies have been conducted in the search for viable solutions to such ills. Therefore, this work has the objective of analyzing the performances of the hydrocarbon (HC) R600a instead of the hydrofluorocarbon (HFC) R134a. For the experiments, an experimental bench of vapor compression refrigeration system was used, in which it simulates an air conditioner. In order to analyze the performance, we used mathematical models based on the first law of thermodynamics and also focused on parameters such as condensation and evaporation pressure, mass flow of the refrigerant, thermal loads of the evaporator, power consumed by the compressor and finally , the coefficient of performance (COP) of the system. The analysis of the results shows that, for the same thermal load, the R600a presented energy efficiency of 9 \% to 11 \% lower than R134a. However, investigating the influence of the rotation of the compressor for each fluid, it was concluded that the substitution is feasible by applications of lower thermal loads, since the R600a presents up to 36 \% higher COP in comparison to R134a
Subject: Sistemas de refrigeração
Hidrocarbonetos
Desempenho
Compressores
Language: Português
Editor: [s.n.]
Citation: CUTRIM, Yuri Alisson Barreto. Avaliação do desempenho de um sistema de refrigeração devido a substituição do fluido refrigerante. 2018. 1 recurso online (79 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/331256>. Acesso em: 3 set. 2018.
Date Issue: 2018