dc.titlePunção em lajes lisas de concreto armado com aberturas : análise experimentalpt_BR
dc.title.alternativePunching shear in reinforced concrete flat slabs with openings : experimental investigationpt_BR
dc.contributor.authorLourenço, Diego da Silva, 1990-pt_BR
dc.contributor.advisorAlmeida, Luiz Carlos de, 1955-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismopt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Engenharia Civilpt_BR
dc.subjectConcreto armadopt_BR
dc.subjectResistencia ao cisalhamentopt_BR
dc.subjectPesquisa experimentalpt_BR
dc.subjectLajes de concretopt_BR
dc.subject.otherlanguageReinforced concreteen
dc.subject.otherlanguageShear strengthen
dc.subject.otherlanguageExperimental researchen
dc.subject.otherlanguageConcrete slabsen
dc.description.abstractResumo: A ruptura por punção ocorre em lajes lisas de concreto armado submetidas a grandes esforços localizados na região do pilar. Esse esforço concentrado na laje leva a formação de uma superfície de cone em volta do pilar formada a partir da interface de contato entre laje e pilar que ocorre de forma frágil. Com o aumento da utilização de lajes lisas e a necessidade da presença de aberturas para a passagem de instalações hidráulicas e elétricas, que reduzem de forma acentuada a capacidade resistente à punção, o entendimento da influência de aberturas nesse tipo de estrutura se torna extremamente necessária. A presença de aberturas pode levar a uma concentração ainda maior de tensões na região entre o pilar e a abertura e mudar o comportamento estrutural da laje. A influência na carga última a punção e no comportamento estrutural do afastamento de aberturas em lajes lisas foi investigada através de cinco lajes quadradas (1800 x 1800 mm) com altura de 130 mm apoiadas em pilares quadrados (150x150mm) ensaiadas até a ruptura. A variável foi o posicionamento da abertura a diferentes distâncias da face do pilar. Os experimentos mostram concentração elevada de tensões na região critica entre o pilar e a abertura e que a partir de 3d a abertura passa a não ter mais influência na carga de ruptura da lajept
dc.description.abstractAbstract: The punching shear failure occurs in reinforced concrete flat slabs subjected to high located stresses in the region around the column. This concentrated load in the slab leads to the formation of a conical surface formed from the contact interface between the slab and the column. The increase in the use of flat slabs and the need of the openings in slabs for the passage of hydraulic and electrical installation, which significantly reduces the punching shear resistance capacity of the slab, makes the understanding of the influence of openings in this type of structure extremely necessary. The presence of openings may lead to an even highly concentration of stresses in the region between the column and the opening and may change the structural behaviour of the slab. The influence on ultimate punching shear resistance and structural behaviour of slabs with openings at different distances from the column was investigated through five square slabs (1800 x 1800 mm) with 130 mm height supported on square columns (150x150mm) tested until rupture. The variable was the positioning of the opening at different distances from the column. The results show high stresses concentration in the critical region between the column and the opening and that openings situated at 3d from the column have no influence on the failure load of the slaben
dc.publisher[s.n.]pt_BR
dc.date.issued2018pt_BR
dc.identifier.citationLOURENÇO, Diego da Silva. Punção em lajes lisas de concreto armado com aberturas: análise experimental. 2018. 1 recurso online (179 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/331186>. Acesso em: 3 set. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreedisciplineEstruturas e Geotécnicapt_BR
dc.description.degreenameMestre em Engenharia Civilpt_BR
dc.contributor.committeepersonalnameTrautwein, Leandro Moutapt_BR
dc.contributor.committeepersonalnameSouza, Rafael Alves dept_BR
dc.date.defense2018-02-19T00:00:00Zpt_BR
dc.date.available2018-09-03T09:50:22Z-
dc.date.accessioned2018-09-03T09:50:22Z-
dc.description.provenanceMade available in DSpace on 2018-09-03T09:50:22Z (GMT). No. of bitstreams: 1 Lourenco_DiegoDaSilva_M.pdf: 38741146 bytes, checksum: a5b2bcc3980cab2b3173ce5fb8944c43 (MD5) Previous issue date: 2018en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/331186-
Appears in Collections:FEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
Lourenco_DiegoDaSilva_M.pdf37.83 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.