Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/331106
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.descriptionOrientador: José Ricardo de Albergaria Barbosapt_BR
dc.descriptionTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicabapt_BR
dc.format.extent1 recurso online (55 p.) : il., digital, arquivo PDF.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languageMultilínguapt_BR
dc.relation.requiresRequisitos do sistema: Software para leitura de arquivo em PDFpt_BR
dc.typeTESE DIGITALpt_BR
dc.titleComparação in vitro do sítio de preparo de implantes dentários com sistema ultrassônico e sistema rotatório convencional = In vitro comparison of dental implant site preparation with ultrasonic system and conventional rotatory systempt_BR
dc.title.alternativeIn vitro comparison of dental implant site preparation with ultrasonic system and conventional rotatory systempt_BR
dc.contributor.authorLanata-Flores, Antonio, 1988-pt_BR
dc.contributor.advisorAlbergaria-Barbosa, José Ricardo de, 1956-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Odontologia de Piracicabapt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Clínica Odontológicapt_BR
dc.subjectProcedimentos cirúrgicos ultrassônicospt_BR
dc.subjectPiezocirurgiapt_BR
dc.subjectImplantes dentáriospt_BR
dc.subjectProcedimentos cirúrgicos bucaispt_BR
dc.subject.otherlanguageUltrasonic surgical proceduresen
dc.subject.otherlanguagePiezosurgeryen
dc.subject.otherlanguageDental implantsen
dc.subject.otherlanguageOral surgical proceduresen
dc.description.abstractResumo: Este estudo teve o objetivo de comparar in vitro o sítio de preparo de implantes dentários realizado com sistema ultrassônico e sistema rotatório convencional por meio da temperatura, o tempo e a estabilidade primária que são fornecidos pelas diferentes sequências de brocas e pontas de implantes dentários. Um total de 16 ostetomias foram realizadas utilizando diferentes seqüências de brocas (Initial, titamax 2.0, 2/3, titamax 3.0. Neodent, Curitiba, Brasil) para o grupo rotatório (GR) e pontas (IM1S, IM2P, IM2 / 3, IM3P. Mectron Medical Technology, Carasco, Itália) para o grupo ultrassônico (GU) em uma amostra de osso corticomedular bovino para grupo. Um protocolo padronizado foi estabelecido para fornecer as condições de trabalho constantes em cada sequência de osteotomia, medindo tempo, temperatura e torque de instalação de implante dentário. A temperatura foi medida por meio de um termômetro digital no sítio da perfuração e um termômetro infravermelho com mira laser no sítio externo da osteotomia. Foram instalados quatro implantes em cada grupo para medir o torque final da instalação do implante com um torquímetro digital (Instrutherm TQ-680, São Paulo, Brasil). Um total de dezesseis osteotomias divididos em dois grupos: grupo rotatório (n = 8) e grupo ultrassônico (n = 8). Os valores médios no grupo GR foram 22,87 segundos para toda a sequência de brocas, 24,21 graus Celsius para temperatura superficial, 27,57 para temperatura de perfuração e 32, 30 N / cm para o torque, entretanto, a média para os valores do grupo GU foi de 72,91 segundos, 26,56 graus Celsius para temperatura superficial, 32,12 graus Celsius para temperatura de perfuração e 22,60 N / cm para torque. Houve diferenças significativas entre os grupos, atingindo maior temperatura e tempos prolongados de osteotomias no grupo ultrassônico. O sistema ultrassônico e o sistema rotatório são métodos eficazes para a preparação do sítio de instalação de implante fornecendo resultados satisfatórios, embora o sistema rotatório seja mais rápido e com menores temperaturas durante osteotomiaspt
dc.description.abstractAbstract: This study aimed to evaluate the temperature variability, time and primary stability that is provided by the different sequences of dental implant drills with ultrasonic system and conventional rotatory system in a corticocancellous bone sample. A total of 16 ostetomies were performed using different sequences of drills (Initial, titamax 2.0, 2/3, titamax 3.0. Neodent, Curitiba, Brazil) for group #1 and tips (IM1S, IM2P, IM2/3, IM3P. Mectron Medical Technology, Carasco, Italy) for group #2 on a bovine corticalcancellous bone sample. A standardized protocol was designed to provide constant working conditions in every sequence after implant installation, measuring time and temperature. Temperature were measured using a digital thermometer in an apical site and an infrared thermometer gun with laser sight in the external osteotomy site. Four implants were installed in each group to measure the final torque of the implant installation with a digital torquemeter (Instrutherm TQ-680, São Paulo, Brasil). The sixteen osteotomies divided in two groups: rotatory group (n=8) and ultrasonic group (n=8) showed mean RG values were for time 22,87 seconds, 24,21 degree Celsius for superficial temperature , 27,57 for perforation temperature and 32,30 N/cm for torque, meanwhile the mean for UG values were 72,91 seconds, 26,56 degree Celsius for superficial temperature , 32,12 degree Celsius for perforation temperature and 22,60 N/cm for torque with significant differences between the group reaching greater temperature and prolonged times of osteotomies in the Ultrasonic group. The ultrasonic and the rotatory system are effective methods for implant site preparation providing satisfactory results although the rotational system consume less time and lower temperatures during osteotomiesen
dc.publisher[s.n.]pt_BR
dc.date.issued2017pt_BR
dc.identifier.citationLANATA-FLORES, Antonio. Comparação in vitro do sítio de preparo de implantes dentários com sistema ultrassônico e sistema rotatório convencional = In vitro comparison of dental implant site preparation with ultrasonic system and conventional rotatory system. 2017. 1 recurso online (55 p.). Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/331106>. Acesso em: 3 set. 2018.pt_BR
dc.description.degreelevelDoutoradopt_BR
dc.description.degreedisciplineCirurgia e Traumatologia Buco-Maxilo-Faciaispt_BR
dc.description.degreenameDoutor em Clínica Odontológicapt_BR
dc.contributor.committeepersonalnameTroia Junior, Manoel Gomespt_BR
dc.contributor.committeepersonalnameCorreia Medeiros, Raquelpt_BR
dc.contributor.committeepersonalnameSantos, Eduardo César Almadapt_BR
dc.contributor.committeepersonalnameAlmeida, José Flávio Affonso dept_BR
dc.date.defense2017-10-30T00:00:00Zpt_BR
dc.description.sponsordocumentnumber140003/2017-7pt_BR
dc.date.available2018-09-03T08:40:01Z-
dc.date.accessioned2018-09-03T08:40:01Z-
dc.description.provenanceMade available in DSpace on 2018-09-03T08:40:01Z (GMT). No. of bitstreams: 1 Flores_AntonioGabrielLanata_D.pdf: 1872105 bytes, checksum: 2475738e70fc0bc4ffb3b5050643ce79 (MD5) Previous issue date: 2017en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/331106-
dc.description.sponsorCNPQpt_BR
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
Flores_AntonioGabrielLanata_D.pdf1.83 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.