Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/330901
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.descriptionOrientador: Simone Andréa Pozzapt_BR
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Tecnologiapt_BR
dc.format.extent1 recurso online (95 p.) : il., digital, arquivo PDF.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.relation.requiresRequisitos do sistema: Software para leitura de arquivo em PDFpt_BR
dc.typeDISSERTAÇÃO DIGITALpt_BR
dc.titleAnálise do impacto da queda de pressão (dP) gerada no sistema de filtração de ar com filtros planos contíguos, variando o espaçamento entre etapaspt_BR
dc.title.alternativeAnalysis of the impact from generated pressure drop (dP) in static air filter contiguous systems varying the space between filter stagespt_BR
dc.contributor.authorAlves, Edmilson Ricardo, 1977-pt_BR
dc.contributor.advisorPozza, Simone Andréa, 1976-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Tecnologiapt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Tecnologiapt_BR
dc.subjectQualidade do ar de interiorespt_BR
dc.subjectAr condicionadopt_BR
dc.subjectAr - Purificaçãopt_BR
dc.subjectVentilaçãopt_BR
dc.subject.otherlanguageIndoor air qualityen
dc.subject.otherlanguageAir conditioningen
dc.subject.otherlanguageAir - Purificationen
dc.subject.otherlanguageVentilationen
dc.description.abstractResumo: Há uma grande demanda de utilização de aparelhos de ar condicionado e ventilação em diversas aplicações, sobretudo em estabelecimentos comerciais e industriais. Ao mesmo tempo, aumenta a preocupação com a qualidade do ar interior (QAI) para melhorar proteção dos ocupantes de ambientes interiores (fechados), que hoje já passam até 90% de seu tempo em ambientes fechados. Não menos importante, o consumo energético tem se tornado uma preocupação governamental nas últimas décadas. Os filtros planos têm importante papel para apoiar a manutenção dos níveis desejados de QAI, além de proteger os processos produtivos, os equipamentos de fabricação e o meio ambiente de contaminações. Muitos equipamentos de aquecimento, ventilação e ar condicionado (AVAC) que os contém utilizam mais de uma etapa de filtração, dispostas em série, com ou sem espaço entre elas, esse último denominado filtros contíguos. Esse trabalho analisou o impacto que a variação desse espaço (distância entre os filtros) pode ter na queda de pressão dos sistemas de filtração de ar equipados com filtros planos. A queda de pressão (?P) do sistema tem relação direta com o consumo energético dos equipamentos, então o objetivo desse trabalho foi trazer informações que possibilitem desenvolver sistemas de filtração de ar mais eficientes em consumo energético. Primeiro determinou-se as constantes de permeabilidade Darciana e não Darciana, do meio filtrante, principal fator para a formação da queda de pressão individual do filtro. Depois foram realizados ensaios variando a distância entre os filtros planos contíguos de 0 a 25,400 mm, com escalas a cada 6,350 mm, e a vazão volumétrica de ar variando de 600 a 3.400 m³/h, com escalas intermediárias de 700 m³/h, para simular velocidades superficiais e de filtração mais comuns em aplicações de AVAC, predominantemente com o fluido escoando em regime turbulento. Repetiram-se os ensaios para diferentes perfis geométricos dos filtros além do plissado plano, como o plissado ondulado e o plissado em "V". Manteve-se o mesmo meio filtrante (a mesma permeabilidade), mesma área filtrante e mesmo passo das plissas, isolando totalmente a distância entre filtros como única variável de estudo. Os resultados das medições de queda de pressão após as variações foram registrados e foram plotadas curvas de ?P em função da vazão e da distância entre filtros. Concluiu-se que a vazão de ar influenciou diretamente a queda de pressão dos filtros individualmente, bem como os resultados dos pares de filtros; a queda de pressão do filtro da segunda etapa foi menor que a do filtro da primeira etapa (que recebe o fluxo de ar primeiramente), em função de perda de energia cinética durante a passagem do fluido pelo filtro. Verificou-se que a queda de pressão dinâmica existe e merece atenção para estudos futuros. Por fim, a variação da distância entre os filtros não influenciou a queda de pressão do sistema, sendo essa influenciada pela permeabilidade do meio filtrante e pelo perfil geométrico (desenho) do filtropt
dc.description.abstractAbstract: There is a large demand for the usage of air conditioning and ventilation devices for several applications, mostly in commercial and industrial facilities. At the same time, it raises the concerns regarding Indoor Air Quality (IAQ) to improve the protection to the indoor environmental occupants, that currently spend until 90% of their times indoor. Not less important, energy consumption it became a concern of the governmental authorities in the last decades. Static filters play an important role to support maintenance of the desired IAQ levels, thus protecting manufacturing processes, production equipment and environment from contaminations. Many heating, ventilation and air conditioning (HVAC) equipment that have them installed may contain more than a filter stage, arranged in series, with or without spaces between filters, the last one named contiguous filters. This work noted the impact that the variation of such space (distance between filters) may have in static air filter system pressure drop in devices equipped with static filters. The static air filter system pressure drop (?P) is related to the equipment energy consumption, so the target of this work was to deliver information that allows the development of more efficient air filtration systems in terms of energy consumption. First it was determined the Darcy and non Darcy permeability constants, for the filter media, major factor for the single filter pressure drop formation. Later, tests were carried out varying the distance of the contiguous filters, from 0 to 25.400 mm, with scales each 6.350 mm and volumetric air flow from 600 to 3,400 m³/h, with intermediate scales of 700 m³/h to simulate the majority of superficial and filtration velocities in HVAC applications, predominantly flowing in turbulent regime. Tests were repeated for different geometry filter profiles rather than pleated shape, "wave" pleated shaped and "V bed filter. It was kept the same filter media (same permeability), same filter area and pleat pitch, fully isolating the distance of filter stages as the only variable of the study. The pressure drop measurements results after the variation were registered, and curves were plotted of the ?P in relation to the filter distances. It was concluded that the air flow has direct influence on the single filter pressure drop, as well as the results found in the filter pairs and that the pressure drop of the second filter was lower than the ?P of the first stage (that receives the air flow first), due to the loss of kinetic force during the flow through the filter. Was verified the existence of the dynamic pressure drop, requiring more attention for future work. Final conclusion was that the distance between filters has no influence on the system pressure drop that however is related to the filter media permeability and the filter geometric profile (filter design)en
dc.publisher[s.n.]pt_BR
dc.date.issued2017pt_BR
dc.identifier.citationALVES, Edmilson Ricardo. Análise do impacto da queda de pressão (dP) gerada no sistema de filtração de ar com filtros planos contíguos, variando o espaçamento entre etapas. 2017. 1 recurso online (95 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Tecnologia, Limeira, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/330901>. Acesso em: 3 set. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreedisciplineAmbientept_BR
dc.description.degreenameMestre em Tecnologiapt_BR
dc.contributor.committeepersonalnameAguiar, Monica Lopes dept_BR
dc.contributor.committeepersonalnamePicone, Carolina Siqueira Francopt_BR
dc.date.defense2017-12-13T00:00:00Zpt_BR
dc.date.available2018-09-03T03:19:40Z-
dc.date.accessioned2018-09-03T03:19:40Z-
dc.description.provenanceMade available in DSpace on 2018-09-03T03:19:40Z (GMT). No. of bitstreams: 1 Alves_EdmilsonRicardo_M.pdf: 2590446 bytes, checksum: 8a685daadcb5c821d06b535b3300bb8e (MD5) Previous issue date: 2017en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/330901-
Appears in Collections:FT - Tese e Dissertação

Files in This Item:
File SizeFormat 
Alves_EdmilsonRicardo_M.pdf2.53 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.