Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/325480
Type: TESE DIGITAL
Title: Análise fotoelástica das tensões em prótese parcial fixa promovidas por diferentes conexões protéticas e alinhamento de implantes osseointegráveis
Title Alternative: Photoelastic analysis of stresses in fixed partial prosthesis promoted by different prosthetic connections and alignment of dental implants
Author: Tonella, Bianca Piccolotto, 1979-
Advisor: Consani, Rafael Leonardo Xediek, 1974-
Abstract: Resumo: O objetivo nete estudo foi analisar as tensões geradas por próteses parciais fixas de três elementos suportadas por diferentes tipos de implantes osseointegráveis (hexágonos externo e interno ou cone Morse) instalados em linha ou em tripodismo. Foram confeccionados seis modelos com resina fotoelástica, nos quais foram instalados três implantes de 4 x 10 mm e igual quantidade de infraestruturas de Ni-Cr com três elementos, parafusadas nos implantes dispostos linearmente ou em tripodismo. As estruturas foram submetidas a cargas pontuais ou simultâneas (axial ou oblíqua de 45º), com intensidade de 100 N. Um polariscópio circular foi utilizado para análise do comportamento fotoelástico durante a aplicação das diferentes cargas. Os resultados foram analisados qualitativa e quantitativamente por meio do programa Fringes®, em plataforma MATLAB. Os dados foram submetidos ao teste ANOVA de dois fatores e Teste de Tukey com nível de significância de 5%. Os resultados demonstraram que houve diferença estatisticamente significante entre os níveis de tensões geradas. Tanto na aplicação das cargas pontuais e simultâneas, axiais e oblíquas; os implantes trípodes apresentaram menores níveis de tensão do que os implantes alinhados, sendo que os implantes de hexágono interno apresentaram menores níveis de tensão, seguidos pelo hexágono externo e cone Morse. Concluiu-se que os implantes hexágonos interno promoveram melhor distribuição das tensões e a posição trípode concentrou menores níveis de tensões

Abstract: The objective of this study was to analyze the stress generated by fixed partial prosthesis with three elements supported with different type of dental implants (external hexagon, internal hexagon or Morse taper) placed in line or offset. To perform this study, six models were made with PL-2 photoelastic resin, in which three implants of 4 x 10 mm, and equal amount of Ni-Cr infrastructure with three elements were linear or offset placed. These structures were subjected to single or simultaneous (axial or oblique in 450) load with intensity of 100 N. A circular polariscope was used to analyze the photoelastic behavior during the application of different loads. The results were analyzed qualitatively and quantitatively with Fringes® plugin software in Matlab platform. ANOVA and Tukey¿s test at 5% significance were performed. Results showed statistically significant differences between the stress levels. The offset implants presented lower stress levels for both single and simultaneous axial or oblique load applications when compared to aligned implants, the lowest stress level was observed with the internal hexagon implants, followed by the external hexagon and Morse taper. In conclusion, the internal hexagon implants promoted better stress distribution and the offset position concentrated lower stress levels
Subject: Implantes dentários
Prótese dentária parcial fixa
Protese dentária fixada por implante
Editor: [s.n.]
Date Issue: 2016
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
Tonella_BiancaPiccolotto_D.pdf1.65 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.