Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/310085
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.identifier(Broch.)pt_BR
dc.descriptionOrientador: Jose Luiz Donatopt_BR
dc.descriptionTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicaspt_BR
dc.format.extent93f.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.typeTESEpt_BR
dc.titleEstudo de biodisponibilidade relativa entre duas formulações de metotrexato em plasma humano utilizando cromatografia liquida acoplada a espetrometria de massas em seriept_BR
dc.title.alternativeLiquid chromatography-mass spectrometry method for determination of methotrexate in human plasmapt_BR
dc.contributor.authorPioto, Ligia Rodriguespt_BR
dc.contributor.advisorDonato, Jose Luizpt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Ciências Médicaspt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Farmacologiapt_BR
dc.subjectEquivalência terapêuticapt_BR
dc.subjectCromatografia líquidapt_BR
dc.subjectEspectrometria de massaspt_BR
dc.subjectBioequivalencept_BR
dc.subject.otherlanguageLiquid chromatographyen
dc.subject.otherlanguageTandem mass spectrometryen
dc.description.abstractResumo: Foi desenvolvido um métdo rápido, sensível e específico para determinação de metotrexato em plasma sanguíneo humano por cromatografia líquida acoplada a espectrometria de massas em série usando folinato de cálcio como padrão interno. O metotrexato foi extraído do plasma humano, utilizando-se precipitação de proteínas plasmáticas com acetonitrila como eluente.O método tem uma corrida cromatográfica de 3,5 minutos usando uma coluna analítica C18 (4,6 mm x 75 mm d.i, 3.5 µm tamanho das partículas) e a curva de calibração foi linear de 10 a 300 ng.mL-1.A recuperação do método de extração foi, em média, de 76,5% e o limite de quantificação para o metotrexato foi de 10 ng.mL-1pt
dc.description.abstractAbstract: A rapid, sensitive and specific method was developed for the determination and quantitation of methotrexate, in human blood plasma by liquid chromatography coupled with tandem mass spectrometry using calcium folinate as internal standard. Methotrexate was extracted from 0,2 mL human plasma by protein precipitation procedure using acetonitrile as eluent. The method included a chromatographic run of 3,5 minutes using a C18 analytical column (4,6 mm x 75 mm i.d., 3.5 µm particle size) and the linear calibration curve over the range from 10 to 300 ng mL-1. Recoveries were greater than 76.5% and the limit of uantitation of methotrexate was 10 ng mL-1en
dc.publisher[s.n.]pt_BR
dc.date.issued2007pt_BR
dc.identifier.citationPIOTO, Ligia Rodrigues. Estudo de biodisponibilidade relativa entre duas formulações de metotrexato em plasma humano utilizando cromatografia liquida acoplada a espetrometria de massas em serie. 2007. 93f. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/310085>. Acesso em: 10 ago. 2018.pt_BR
dc.description.degreelevelDoutoradopt_BR
dc.description.degreenameMestre em Farmacologiapt_BR
dc.contributor.committeepersonalnameMoreno, Ronilson Agnaldopt_BR
dc.contributor.committeepersonalnamePaschoal, Sisi Marcondespt_BR
dc.date.defense2007-01-15T00:00:00Zpt_BR
dc.date.available2018-08-10T07:16:04Z-
dc.date.accessioned2018-08-10T07:16:04Z-
dc.description.provenanceMade available in DSpace on 2018-08-10T07:16:04Z (GMT). No. of bitstreams: 1 Pioto_LigiaRodrigues_D.pdf: 680751 bytes, checksum: 6d472989ce55c9ad510ce3f7fffb6630 (MD5) Previous issue date: 2007en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/310085-
Appears in Collections:FCM - Tese e Dissertação

Files in This Item:
File SizeFormat 
Pioto_LigiaRodrigues_D.pdf664.8 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.