Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/304943
Type: TESE DIGITAL
Degree Level: Doutorado
Title: Análise, por meio da extensometria elétrica, das deformações da estrutura e dos análogos de implantes, na região anterior da maxila, após carga progressiva
Title Alternative: Analysis of structure and dental implants analogues deformations on the aesthetic area of the upper jaw, by strain gauges, after progressive load
Author: Ciotti, Danilo Lazzari, 1976-
Advisor: Silva, Wilkens Aurelio Buarque e, 1967-
Abstract: Resumo: O objetivo neste trabalho foi avaliar, por meio da técnica da extensometria elétrica, as deformações ocorridas nos análogos de implantes e nas infraestruturas metálicas de próteses parciais fixas, que foram posicionados na região dos quatro incisivos superiores com variação na disposição e na configuração protética. Foram confeccionadas duas infraestruturas: corpo-de-prova I - infraestrutura metálica fixada sobre os análogos de implantes na região dos incisivos laterais, e a região dos incisivos centrais correspondentes ao pôntico, formando uma estrutura fixa de 4 elementos; corpo-de-prova II - infraestrutura metálica fixada sobre os análogos de implantes na região dos incisivos centrais, e a região dos incisivos laterais correspondentes aos cantilevers, formando uma estrutura fixa de 4 elementos. Os extensômetros elétricos foram posicionados nas regiões cérvico-vestibular e cérvico-palatina dos análogos. Os corpos-de-prova foram submetidos à carga progressiva até 150N em angulação de 45 graus na superfície palatina na região de contato entre os dois incisivos centrais, simulando oclusão funcional aleatória. Como resultado, foi observado que todos os extensômetros registraram deformação com características de compressão ou tração. Nota-se ainda que houve diferenças entre os resultados nos análogos dos implantes e estrutura, sendo que nos análogos observamos diferenças estatísticas, entre as faces vestibulares e palatinas e em relação à posição da fixação estar na região central ou lateral. Nas estruturas não houve diferenças estatísticas significantes. Podemos concluir que todos os extensômetros registraram deformação, e que os corpos de prova que receberam forças em 45 graus entre os incisivos centrais, os implantes receberam maiores transmissões de força do que a estrutura, e que o posicionamento da fixação na região dos incisivos centrais, aumentou a tensão nos implantes dessa região, com tendência de que o posicionamento da fixação na região dos incisivos laterais leva a uma diminuição da tensão nos implantes, mas aumenta na estrutura

Abstract: The objective of this study was to evaluate, through the electrical strain gauge technology, deformations occurring in the implant analogs and the metallic infrastructure of fixed partial dentures, fixed on these implants, which were positioned in the area of ??the four maxillary incisors with variation in layout and prosthetic configuration. Were prepared for this purpose two infrastructures: test body I - metal infrastructure fixed on the implant analogues in the region of the lateral incisor, and central incisor region corresponding to the pontic forming a fixed structure 4 elements; test body II - metal infrastructure fixed on the implant analogues in the region of the central incisor and the region corresponding to the lateral incisors cantleveres, forming a fixed structure of 4 elements. The strain gauges were placed on cervical-vestibular and cervical cleft of similar regions. The specimens were subjected to progressive load of 150N at an angle of 45 ° in the palatal surface in the contact area between the two central incisors, simulating a random functional occlusion. As a result, it was observed that all gauges recorded deformation with compression characteristics and traction. Note also that there were differences between the results in implants and structure, and the implants observe statistical differences between the buccal surfaces and palatine and the place position is in the center or in the lateral region. The structures there were no significant statistical differences. We conclude that FPDs receiving forces in 45 degrees between the central incisors, implants suffered greater force transmissions of the structure, and the positioning of the fixation in the region of the central incisors, leads to an increase of stress in the implants that region. And suggests that the positioning of the fixation in the region of the lateral incisors leads to a decrease of stress on implants, but increases the stress on the structure
Subject: Implantes dentários
Biomecânica
Prótese dentária parcial fixa
Editor: [s.n.]
Citation: CIOTTI, Danilo Lazzari. Análise, por meio da extensometria elétrica, das deformações da estrutura e dos análogos de implantes, na região anterior da maxila, após carga progressiva. 2016. 1 recurso online ( 62 p.). Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/304943>. Acesso em: 30 ago. 2018.
Date Issue: 2016
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
Ciotti_DaniloLazzari_D.pdf1.2 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.