Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/288993
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.identifier(Broch.)pt_BR
dc.descriptionOrientador: Francisco Haiter Netopt_BR
dc.descriptionTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicabapt_BR
dc.format.extent89fls. : il.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.typeTESEpt_BR
dc.titleAvaliação da espessura da camada de imagem de tres tomografos odontologicos convencionaispt_BR
dc.contributor.authorCarneiro Junior, Elcio Gomespt_BR
dc.contributor.advisorHaiter Neto, Francisco, 1964-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Odontologia de Piracicabapt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Radiologia Odontológicapt_BR
dc.subjectTomografiapt_BR
dc.subjectRadiografiapt_BR
dc.subjectDiagnóstico por imagempt_BR
dc.subject.otherlanguageRadiographyen
dc.subject.otherlanguageDiagnostic imagingen
dc.subject.otherlanguageTomographyen
dc.description.abstractResumo: Este estudo tem por objetivo para comparar 3 tipos de imagem em cortes transversais. Foram utilizadas na pesquisa sete mandíbulas humanas secas e desdentadas na região de primeiro molar inferior. Nesta região, foram colocados marcadores radiopacos espaçados um do outro. Foram realizadas tomografias da região de primeiro molar inferior, utilizando diferentes espessuras de corte de três Tomógrafos Odontológicos Convencionais. Cada equipamento realizou um tipo de movimento tomográfico diferente: O aparelho Instrumentarium OP 100 realizou movimento linear, o aparelho Planmeca PROMAX realizou movimento linear corrigido e o aparelho Soredex TOME movimento espiral. Cinco avaliadores analisaram imagens produzidas e deram notas às imagens. Os dados foram submetidos à análise estatística. Comparando os aparelhos, foi possível verificar que o tipo de movimento tomográfico não alterou a nitidez imagem tomográfica. A comparação das imagens por espessura de corte foi possível verificar que o aparelho OP 100, gerou valores mais próximos aos relatados pelos fabricantes. Também, a espessura da camada de borramento foi variável dependendo da espessura de cortept
dc.description.abstractAbstract: This study was designed to compare 3 modalities of cross-seccional imaging. On this work seven dry human mandibles on the first molar region were used. In this region radiopacs markers were placed within space between each marker. Some Tomography¿s exams were made at the first inferior molar, using different cut¿s thickness images from three conventional tomograph¿s machines. Each equipment had a different type of tomographic movement: the Instrumentarium OP 100 had a linear movement, the Planmeca PROMAX had a true linear movement and the Soredex TOME had the multidirectional movement. Five radiologists evaluated and scored the images. The data were submitted into a statistic¿s analysis. Comparing the machines, it was possible to verify that the tomography movement type had no effect on the diagnostic accuracy and quality. However comparing the images by cut¿s thickness, it was possible to verify that the OP 100 machine had the cut¿s thickness similar to manufacturer report. Moreover, depending on the cut¿s thickness the blurry layers varyen
dc.publisher[s.n.]pt_BR
dc.date.issued2005pt_BR
dc.identifier.citationCARNEIRO JUNIOR, Elcio Gomes. Avaliação da espessura da camada de imagem de tres tomografos odontologicos convencionais. 2005. 89fls. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/288993>. Acesso em: 4 ago. 2018.pt_BR
dc.description.degreelevelDoutoradopt_BR
dc.description.degreedisciplineRadiologia Odontologicapt_BR
dc.description.degreenameDoutor em Radiologia Odontológicapt_BR
dc.contributor.committeepersonalnameBoscolo, Frab Norbertopt_BR
dc.contributor.committeepersonalnameCoclete, Gilberto Aparecidopt_BR
dc.contributor.committeepersonalnameAlbergaria-Barbosa, José Ricardo dept_BR
dc.contributor.committeepersonalnameCastilho, Julio Cezar de Melopt_BR
dc.date.defense2005-11-03T00:00:00Zpt_BR
dc.date.available2018-08-04T04:17:39Z-
dc.date.accessioned2018-08-04T04:17:39Z-
dc.description.provenanceMade available in DSpace on 2018-08-04T04:17:39Z (GMT). No. of bitstreams: 1 CarneiroJunior_ElcioGomes_D.pdf: 4148945 bytes, checksum: 58cc0adb69ac56b9a8d827362333bfcf (MD5) Previous issue date: 2005en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/288993-
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
CarneiroJunior_ElcioGomes_D.pdf4.05 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.