Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/288984
Type: TESE
Degree Level: Doutorado
Title: Influencia do tempo de espera, de exposição e condições de luz em imagens obtidas por placas de armazenamento de fosforo
Title Alternative: Influence of the time and storage conditions on images acquired using phosphor storage plates
Author: Martins, Mauro Guilherme de Barros Quirino
Advisor: Haiter Neto, Francisco, 1964-
Abstract: Resumo: O objetivo deste estudo foi verificar a influência do tempo de espera, tempo de exposição e condição de luz na qualidade final de imagens obtidas por placas de fósforo dos sistemas digitais DenOptix®, Digora® e Vistascan®. As placas foram sensibilizadas com uma escala de densidade, com a finalidade de realizar as análises objetivas, com um ¿phantom¿, constituído a partir de uma mandíbula macerada, para análise subjetiva e com dentes pré-molares, para o diagnóstico de cáries. As análises objetivas foram realizadas pelo valor do pixel dos softwares correspondentes aos sistemas digitais e estes dados, analisados estatisticamente pelos testes de Tukey e Dunnet. A análise subjetiva foi realizada por 3 radiologistas e os dados submetidos ao teste de Mann Whitney. Para o diagnóstico de cáries, foram utilizados oito avaliadores e os dados submetidos aos testes de Wilcoxom e Friedman. Como conclusões: 1. As imagens obtidas pelo sistema Digora® sofreram perda de qualidade de imagem a partir de 4 horas, após a exposição aos raios X; 2. O sistema DenOptix® apresentou-se estável quando submetido a diferentes tempos de exposição adequados e tempos de espera; 3. A qualidade da imagem das placas de armazenamento de fósforo é afetada pela qualidade dos invólucros plásticos disponíveis em cada sistema. Os invólucros do sistema Vistascan® foram capazes de proteger entrada de luz nas condições utilizadas por este estudo

Abstract: The aim of this study was to verify the influence of the delay in scanning, exposure time and light condition in the final quality of images obtained using phosphor storage plates of DenOptix®, Digora® and Vistascan® digital systems. The plates were radiographed with an aluminium step wedge for the objective analysis, with a dry mandible for the subjective analysis and with premolars teeth for caries diagnosis. The objective analysis were carried through by the pixel value obtained from the corresponding softwares of each digital systems and these data analyzed statistically by Tukey and Dunnet tests. The subjective analysis were carried through by 3 radiologists and the data submitted to Mann Whitney U test. For caries diagnosis, eight observers were used and the data submitted to Wilcoxom and Friedman tests. As conclusions: 1. The images obtained using the Digora® system showed loss of quality of image at 4 hours after exposure; 2. The DenOptix® system presented a certain stability when subjected to different delays in scanning and exposure times; 3. The quality of the image of the phosphor storage plates is affected by the quality of the available plastic hygienic bags of each system. The bags of the Vistascan® system were able to protect under all the conditions used in this study
Subject: Dentes - Radiografia
Sistemas digitais
Language: Português
Editor: [s.n.]
Citation: MARTINS, Mauro Guilherme de Barros Quirino. Influencia do tempo de espera, de exposição e condições de luz em imagens obtidas por placas de armazenamento de fosforo. 2005. 63p. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/288984>. Acesso em: 10 ago. 2018.
Date Issue: 2005
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
Martins_MauroGuilhermedeBarrosQuirino_D.pdf448.26 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.