Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/288547
Type: DISSERTAÇÃO
Degree Level: Mestrado
Title: Análise fotoelástica das tensões induzidas em prótese total inferior reembasada com materiais permanentes resiliente e rígido
Title Alternative: Photoelastic analysis of stresses induced in lower denture lined with permanent soft and hard materials
Author: Pereira, Izabella Patta, 1986-
Advisor: Consani, Rafael Leonardo Xediek, 1974-
Abstract: Resumo: O objetivo neste estudo experimental in vitro foi avaliar o comportamento das tensões induzidas nas estruturas de suporte de prótese total, por meio da análise fotoelástica nas seguintes condições: Grupo 1- prótese total convencional, Grupo 2- prótese total convencional reembasada com material rígido permanente à base de resina acrílica e Grupo 3- prótese total convencional reembasada com material resiliente permanente à base de silicone. Para este experimento foram confeccionadas três próteses totais inferiores e uma prótese total superior, possibilitando que os testes fotoelásticos fossem conduzidos com as próteses em posição de máxima intercuspidação habitual. Foram feitos carregamentos axiais no modelo fotoelástico mandibular com cargas de 10, 20 e 30 kgf /cm! em cada corpo-deprova. O Grupo 1 apresentou tensões em toda extensão do rebordo, com maior ênfase na região anterior e lateral esquerda e menor tensão na lateral direita. Na região lateral esquerda, o Grupo 2 apresentou tensões similares ao Grupo 1 nas regiões de pré-molares e trígono retromolar. O Grupo 3 exibiu diminuição das ordens de franja e distribuição homogênea de tensões induzidas. Concluiu-se que prótese total convencional e a prótese total convencional reembasada com material à base de resina acrílica geraram tensões pontuais, podendo acarretar maior reabsorção do tecido ósseo. Já o material reembasador à base de silicone proporcionou distribuição mais homogênea das tensões induzidas pela prótese

Abstract: The aim of this experimental in vitro study was to evaluate the behavior of the stresses induced in the supporting structures of denture through the photoelastic method in the following conditions: Group 1- conventional denture, Group 2- conventional denture relined with hard chairside reline resin and Group 3- conventional denture relined with resilient material silicone-based. For this experiment were made three lower dentures and a maxillary one. The photoelastic tests were conducted with the prosthesis in position of maximum intercuspation. Loads were made in axial position. The mandibular photoelastic model was loaded with 10, 20 and 30 kgf/cm! in each specimen. The Group 1 showed stresses all along the model, with greater emphasis on the anterior and left lateral and less strain on the right side. In the left lateral surface, Group 2 showed similar as Group 1, with stresses in the region of premolar and retromolar trigone. The Group 3 exhibited decreased of fringe orders and homogeneous distribution of induced stresses. It was concluded that the first and the second groups generated punctual tensions, which may cause increased bone resorption. The relining material based on silicone provided more homogeneous distribution of the stresses induced by the prosthesis
Subject: Reabilitação
Perda do osso alveolar
Polímeros
Mandibula
Language: Português
Editor: [s.n.]
Date Issue: 2012
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
Pereira_IzabellaPatta_M.pdf226.76 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.