Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/288273
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.identifier(Broch.)pt_BR
dc.descriptionOrientador : Mauro Antonio de Arruda Nobilopt_BR
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicabapt_BR
dc.format.extent77f. : il.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.typeDISSERTAÇÃOpt_BR
dc.titleAnalise do assentamento passivo de infra-estruturas implanto-suportadas obtidas pelas tecnicas do cilindro cimentado e soldado a laserpt_BR
dc.contributor.authorKleine, Alessandrapt_BR
dc.contributor.advisorNóbilo, Mauro Antonio de Arruda, 1965-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Odontologia de Piracicabapt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Clínica Odontológicapt_BR
dc.subjectPrótese dentáriapt_BR
dc.subjectImplantes dentários endoósseospt_BR
dc.description.abstractResumo: Este estudo avaliou o assentamento passivo de infra-estruturas de próteses fixas implanto-suportadas, confeccionadas pelas técnicas do cilindro cimentado e soldado a laser. Para tanto, em um arco mandibular edêntulo, construído em aço-cromo, foram fixados cinco análogos de pilares tipo esteticone. Foram obtidos modelos mestres em gesso tipo V (Exadur@ - Polidental). Sobre os modelos, onde estavam incorporadas as réplicas de pilares, foram realizados os procedimentos de enceramento. Foram confeccionadas 20 estruturas metálicas fundidas em titânio comercialmente puro (Tritan@-Dentaurum Pforzhein - Germany), divididas em dois grupos, onde foram confeccionados alívios internos nas estruturas, que permitiram a adaptação dos cilindros de titânio (1 1 l-CNB Conexão Sistemas de Próteses). No grupo dos cilindros soldados, estes foram fixados com resina acrílica (Duralay@) e posteriormente soldados a laser. No grupo dos cilindros cimentados, apenas o cilindro central foi soldado a laser, e os demais cimentados com cimento resinoso (Panavia F@ - Kuraray Co.) As mensurações foram realizadas com auxílio de um microscópio mensurador (STM Digital- Olympus - Japan), com precisão de 0,0005 mm. Os resultados foram submetidos à análise de variância (ANOV A) e ao teste estatístico F, em nível de 5% de probabilidade, demonstrando que para a posição central, o assentamento passivo foi melhor para o grupo «cimentado" (desajuste médio de 25,60::t12,54!J.m) em relação ao grupo «soldado" (99,06::t50,47!J.ffi), p<0,05. Do mesmo modo, em relação à posição distal, o desajuste médio foi menor para o grupo "cimentado" (29,17::t16,16!J.m) em relação ao grupo "soldado" (70,21::t56,70!J.m), p<0,05. A técnica dos cilindros cimentados foi a que apresentou melhores resultados de assentamento passivopt
dc.description.abstractAbstract: The aim of this study was to evaluate the passive fit of fixed implant supported prosthesis titanium frameworks using the cemented cylinder and laser welded cylinder techniques. Thus, in an edentulous mandibular arch, constructed with "chromium steel", five analogous were fixed, parallels, 10mm apart, center to center. Twenty master casts were obtained in dental stone type V (Exadur@ - Polidental). Above the casts where the implant replies were incorporated, the procedures of waxing were made. Twenty frameworks were made and cast in commercially pure titanium (Tritan@-Dentaurum, Pforzhein-Germany) and divided in two groups. In both of then "small canals" were made in the frameworks, that permitted the titanium cylinders' fit. In the laser welded cylinders' group, alI the samples were fixed with acrylic resin (Duralay@-Reliance Dental Co) and after laser welded. In the cemented cylinders' group, only the central cylinder was fixed with acrylic resin and laser welded and the others were cemented with anaerobe resin (panavia F@ - Kuraray Co.). The interfaces' evaluation and measurements were performed using a measurer microscope (Olympus-Japan) with O.OOO5mm of precision. The results were submitted to ANOV A and test F (p<O.O5), showing that, for the central cylinder, the passive fit Was better for the cemented group (mean ill-fit = 25.60:t12.54f.1m) with regard to welded cylinders' group (99.06:t50.47J.1ffi), p<O.O5. In this way, for the distal cylinder, the ill-fit average Was lower for the cemented group (29.17:t16.16f.1m) than welded group (70.21:t56.70J.1ffi), p<O.O5. The cemented cylinders' technique presented the best results of passive fiten
dc.publisher[s.n.]pt_BR
dc.date.issued2002pt_BR
dc.identifier.citationKLEINE, Alessandra. Analise do assentamento passivo de infra-estruturas implanto-suportadas obtidas pelas tecnicas do cilindro cimentado e soldado a laser. 2002. 77f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/288273>. Acesso em: 2 ago. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreedisciplineProtese Dentalpt_BR
dc.description.degreenameMestre em Clínica Odontológicapt_BR
dc.contributor.committeepersonalnameRibeiro, Ricardo Fariapt_BR
dc.contributor.committeepersonalnameMesquita, Marcelo Ferrazpt_BR
dc.date.defense2002-11-11T00:00:00Zpt_BR
dc.date.available2018-08-02T19:34:10Z-
dc.date.accessioned2018-08-02T19:34:10Z-
dc.description.provenanceMade available in DSpace on 2018-08-02T19:34:10Z (GMT). No. of bitstreams: 1 Kleine_Alessandra_M.pdf: 4693471 bytes, checksum: b0b2b120d9e930bfce154e58a35bc7aa (MD5) Previous issue date: 2002en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/288273-
Appears in Collections:FOP - Tese e Dissertação

Files in This Item:
File SizeFormat 
Kleine_Alessandra_M.pdf4.58 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.