Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/266456
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.identifier(Broch.)pt_BR
dc.descriptionOrientadores : Edson Tomaz, Marco Aurelio Cremascopt_BR
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimicapt_BR
dc.format.extent128p. : il.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.typeDISSERTAÇÃOpt_BR
dc.titleAmostragem passiva de benzeno : presente na atmosferapt_BR
dc.contributor.authorGheleri, Luci Carlapt_BR
dc.contributor.advisorTomaz, Edson, 1963-pt_BR
dc.contributor.coadvisorCremasco, Marco Aurelio, 1962-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Engenharia Quimicapt_BR
dc.subjectCompostos orgânicos voláteispt_BR
dc.subjectAmostragem ambientalpt_BR
dc.subjectAr - Análisept_BR
dc.subjectBenzenopt_BR
dc.description.abstractResumo: Neste trabalho foi avaliado o emprego de amostradores passivos para monitoramento ambiental. O benzeno foi escolhido como composto traçador escolhido. As amostragens foram realizadas na área industrial de Paulínia e na Vila Carioca, em São Paulo, em um local próximo a uma base de armazenamento e distribuição de derivados do petróleo. Também foram realizados testes em laboratório utilizando atmosfera artificial. A amostragem passiva foi realizada simultaneamente com a amostragem ativa, a qual foi utilizada como método referência para comparação dos resultados. As amostras foram analisadas utilizando um dessorvedor térmico acoplado a um cromatógrafo gasoso com detector de ionização em chama. Os resultados deste trabalho mostram que a equação simplificada da amostragem passiva não representa adequadamente o processo da amostragem passiva. Constatou-se que ocorre variação da taxa de amostragem (123,34 a 0,70 ng ppm-1 min-1) com o tempo de amostragem e que esta variação é maior no início do processo de amostragem. Comprovou-se, experimentalmente, que o fenômeno da difusão reversa ocorre, principalmente na fase final do período de amostragem. A partir dos resultados obtidos em campo, uma correlação empírica foi proposta para a taxa de amostragem específica para a amostragem passiva de benzeno. Esta correlação proposta pode ser utilizada com bons resultados em diferentes locais e épocas. Para minimizar os erros, na predição da concentração, sugere-se tempos de amostragem entre 4 e 14 dias, para evitar influência excessiva da taxa de amostragem nos primeiros dias e influência negativa da difusão reversa no final do períodopt
dc.description.abstractAbstract: In this work it has been evaluated the passive samplers application to environmental monitoring. The benzene has been chose as the tracer compound. The samplings have been performed in the Paulínia industrial area and Vila Carioca, in São Paulo, close to a storage and supply base of fuel. Also it has been performed tests in laboratory using artificial atmosphere. The passive sampling has been performed simultaneously with the active sampling, which has been used as reference method to comparison of the results. The samples have been analyzed using a thermal desorber coupled to a gas chromatograph with flame ionization detector. The results of this work show that the passive sampling simplified equation don't represent adequately the passive sampling processo It has been verified that occur the variation of the uptake rate (123,34 to 0,70 ng ppm-1 min-1) with the sampling time and that this variation is higher in the beginning of the sampling processo It has been proved experimentally that the reverse diffusion phenomenon occurs, mainly in the final phase of the sampling period. From the results obtained in the field, the empirical correlation was proposed to the specific uptake rate for benzene passive sampling. The correlation proposed may be used with good results for different sites and periods . To reduce the errors in the concentration prediction, it suggests sampling times among 4 and 14 days, to avoid excessive influences of uptake rate in the first days as well as the negative influence of the reverse diffusion at the end of the perioden
dc.publisher[s.n.]pt_BR
dc.date.issued2003pt_BR
dc.identifier.citationGHELERI, Luci Carla. Amostragem passiva de benzeno: presente na atmosfera. 2003. 128p. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/266456>. Acesso em: 3 ago. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreedisciplineDesenvolvimento de Processos Químicospt_BR
dc.description.degreenameMestre em Engenharia Químicapt_BR
dc.contributor.committeepersonalnameSilva, Meuris Gurgel Carlos dapt_BR
dc.contributor.committeepersonalnameGuimarães, José Robertopt_BR
dc.date.defense2003-12-17T00:00:00Zpt_BR
dc.date.available2018-08-03T23:59:54Z-
dc.date.accessioned2018-08-03T23:59:54Z-
dc.description.provenanceMade available in DSpace on 2018-08-03T23:59:54Z (GMT). No. of bitstreams: 1 Gheleri_LuciCarla_M.pdf: 4606267 bytes, checksum: e48b36034f0ccef3c93fcec14ad7b9d0 (MD5) Previous issue date: 2003en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/266456-
Appears in Collections:FEQ - Tese e Dissertação

Files in This Item:
File SizeFormat 
Gheleri_LuciCarla_M.pdf4.5 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.