Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/262881
Type: DISSERTAÇÃO
Degree Level: Mestrado
Title: Metodologia para avaliação da interface biomaterial/tecido osseo : estudo teorico e experimental
Author: Mariolani, Jose Ricardo Lenzi
Advisor: Arruda, Antonio Celso Fonseca de, 1948-
Abstract: Resumo: Com o objetivo de se desenvolver uma metodologia simples e de baixo custo para o estudo da interface biomaterial/tecido ósseo foram implantados em fêmures de cães pinos de aço inoxidável 316L revestidos com AI2O3, TiO2, Nb2O5 e sem revestimento. Após períodos de seguimento de até 52 semanas, amostras de osso com os implantes foram radiografadas por técnica convencional e de, alta resolução. A seguir, foram obtidas microrradiografias de fatias das amostras e medidas suas densidades ópticas (microdensitometria). As amostras foram ainda analisadas por espectrometria de fluorescência de raios X. Observou-se que a maior parte dos implantes apresentava-se solta e com sinais de reabsorção óssea. A radiografia convencional mostrou-se inadequada para avaliação da interface, enquanto que a técnica de alta resolução produziu imagens mais nítidas e permitiu boa avaliação preliminar. A microrradiografia permitiu nítida visão do tecido formado ao redor do implante e a microdensitometria a medição precisa da espessura do mesmo. Estes dados, juntamente com os resultados da espectrometria de fluorescência de raios X (que acusou a liberação de materiais pelos implantes), permitir'am uma avaliação global da interface e uma análise crítica das vantagens e limitações da metodologia proposta

Abstract: Plugs of stainless steel cOnted with AI2O3, TiO2, Nb2O5 without coating were inserted into canine femora in order to allow the development of a simple and low cost methodology for analysing the interface biomaterial-bone. After follow-up periods of until 52 weeks, bone segments containing the plugs were radiographed using the conventional and high resolution techniques. Next, microradiographs of slices of the bone-plug specimens were taken and after this the optical densities of the films. were measured (microdensitometry). The specimens-were also ana~ysed by X-ray fluorescence s~ectrometry. At the death of the animaIs it was realized that the majority of the plugs was loosened and exhibited marks of bone resorption. The results of that study showed that the conventional radiographic technique is inappropriate for the evaluation of the intertace, as long as the high resolution radiographic technique produced sharper images and allowed a good preliminary evaluation. The microradiography. aIlowed a clear view of the tissue fbrmed around the implant and the microdensitometry allowed the precise measurement of its thickness. These informations added to spectrometry analysis the implants) allowed critical analysis of the results of the X-ray fluorescence (which showed the release of material by a global evaluation of the interface and a the advantages and limitations of the proposed methodology
Subject: Materiais
Engenharia mecânica
Language: Português
Editor: [s.n.]
Citation: MARIOLANI, Jose Ricardo Lenzi. Metodologia para avaliação da interface biomaterial/tecido osseo: estudo teorico e experimental. 1991. [113]f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/262881>. Acesso em: 13 jul. 2018.
Date Issue: 1991
Appears in Collections:FEM - Tese e Dissertação

Files in This Item:
File SizeFormat 
Mariolani_JoseRicardoLenzi_M.pdf6.28 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.