Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/262031
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.identifier(Broch.)pt_BR
dc.descriptionOrientador: Carlos Alberto dos Reis Filhopt_BR
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computaçãopt_BR
dc.format.extent100p. : il.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.typeDISSERTAÇÃOpt_BR
dc.titleDeterminação da força peso, a partir dos impactos de pisadas, utilizando um sensor piezoeletricopt_BR
dc.title.alternativeCalculation of weight from step impacts, using a piezoelectric sensorpt_BR
dc.contributor.authorNadalin, Everton Zaccariapt_BR
dc.contributor.advisorReis Filho, Carlos Alberto dos, 1950-pt_BR
dc.contributor.advisorFilho, Carlos Alberto dos Reispt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Engenharia Elétricapt_BR
dc.subjectBovino de corte - Pesos e medidaspt_BR
dc.subjectDispositivos piezoelétricospt_BR
dc.subjectLocomoção animalpt_BR
dc.subject.otherlanguagePiezo sensoren
dc.subject.otherlanguageCattle weightingen
dc.subject.otherlanguageQuadrupedal locomotionen
dc.subject.otherlanguageBipedal locomotionen
dc.description.abstractResumo: Este trabalho está relacionado com o problema da pesagem de um bovino criado em campo aberto, não confinado, destinado ao corte. O conhecimento da evolução contínua do peso do animal é de grande importância neste ramo de negócios e uma solução tecnicamente satisfatória, de custo aceitável e de tecnologia proprietária, certamente representa uma significativa contribuição ao Brasil. Uma solução idealizada, que é a meta maior do projeto em que este trabalho se enquadra, prevê o uso de um dispositivo instalado nas patas do animal, contendo um sensor de pressão ou de impacto e uma unidade eletrônica local que condiciona, digitaliza e armazena os sinais do sensor. Além disto, a unidade eletrônica transmite estes dados através de uma rede de comunicação de dados sem fio e de baixo consumo de energia para centrais de coleta e processamento estrategicamente situadas na área em que o gado se desenvolve. Tal sistema viabiliza, deste modo, acumular no tempo as informações de cada pisada de cada animal. O sinal produzido por um sensor em conseqüência do impacto de cada pisada é influenciado por diversos parâmetros, dentre os quais o peso do animal. Sendo assim, é impossível estabelecer uma relação direta e exclusiva entre o sinal do sensor e o peso. Entretanto, os valores acumulados destes sinais descrevem uma função de múltiplas variáveis que pode ser tratada juntamente com algumas informações complementares sobre o ambiente, buscando-se o isolamento da variável peso. Para isto, uma abordagem adequada prevê o desenvolvimento ou adoção de um modelo do mecanismo de movimentação do animal e o tratamento numérico dos dados acumulados aplicando filtragens e buscas de correlações. Trata-se, portanto, de uma solução de natureza multidisciplinar, que exige uma aliança de conhecimentos complementares para a sua realização. Coube ao presente trabalho, desenvolvido no âmbito da engenharia eletrônica, a implementação de uma etapa preliminar e necessária que consiste de um sistema de caracterização de pisadas constituído de um conjunto de sensores piezoelétricos, uma interface que permite a transferência dos dados destes sensores a um computador e um ambiente de software através do qual foram testados algoritmos para a verificação de correlação entre os sinais associados às pisadas e o peso do agente. São frutos deste trabalho um sistema de coleta automática dos sinais de pisadas, que permitiu a captura de sinais com sensores instalados tanto numa plataforma fixa como num sapato tênis, e um estudo comparativo dos resultados obtidos de tratamentos numéricos distintos aplicados aos dados experimentaispt
dc.description.abstractAbstract: This work deals with the problem of weighting non-confined cattle raised in open field for meat production. The knowledge of the continuous weight change of the animal is of great importance in this business field. Therefore, a technically satisfactory solution, with acceptable price and customized technology, certainly represents a significant contribution to Brazil. The idealized solution, which is the major goal to be pursued by the project in which this work takes part, considers the use of a device placed into the animal¿s hooves. It would contain a pressure or impact sensor and a local electronic unit, which conditions, digitizes and stores the signals received from the sensor. The electronic unit also transmits this data through a low-energy wireless communication network to reception and processing stations placed strategically around the area where the cattle raises. Such a system enables accumulating data about the steps of each animal throughout time. Several parameters, including the animal¿s weight, influence the signal produced by a sensor as a consequence to the impact of a step. Therefore, it is impossible to establish a direct and exclusive relation between the signal given by the sensor and the weight. Nevertheless, the accumulated data of these signals describe a multiple variable function that can be treated together with some complementary information about the environment, seeking the isolation of the weight variable. An adequate approach predicts the development or use of a model of the animal¿s locomotion mechanism and the numeric treatment of the accumulated data by applying filtering and seeking correlations. The multidisciplinary nature of this solution demands an alliance of complementary knowledge for its accomplishment. This work, developed in the scope of electrical engineering, implemented a necessary and preliminary stage that consists of: a step characterization system, made of a set of piezoelectric sensors, an interface that allows transferring data from the sensors to a computer and a software environment, in which algorithms were tested to verify the correlation between the signals associated to the steps and the agent¿s weight. The main result of this work are a system that performs automatic collecting of steps, which allowed the capture of the signals with sensors installed both on a fixed platform and inside tennis shoes, and the comparative study of the results of different numerical treatments applied to the experimental dataen
dc.publisher[s.n.]pt_BR
dc.date.issued2007pt_BR
dc.identifier.citationNADALIN, Everton Zaccaria. Determinação da força peso, a partir dos impactos de pisadas, utilizando um sensor piezoeletrico. 2007. 100p. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/262031>. Acesso em: 10 ago. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreedisciplineEletrônica, Microeletrônica e Optoeletrônicapt_BR
dc.description.degreenameMestre em Engenharia Elétricapt_BR
dc.contributor.committeepersonalnameSequeira, Julio Lopespt_BR
dc.contributor.committeepersonalnameZampieri, Douglas Eduardopt_BR
dc.contributor.committeepersonalnameAttux, Romis Ribeiro de Faissolpt_BR
dc.date.defense2007-10-26T00:00:00Zpt_BR
dc.date.available2018-08-10T09:10:45Z-
dc.date.accessioned2018-08-10T09:10:45Z-
dc.description.provenanceMade available in DSpace on 2018-08-10T09:10:45Z (GMT). No. of bitstreams: 1 Nadalin_EvertonZaccaria_M.pdf: 2191420 bytes, checksum: 38decb6d182261bd5e5fc2df03ad1b9a (MD5) Previous issue date: 2007en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/262031-
Appears in Collections:FEEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
Nadalin_EvertonZaccaria_M.pdf2.14 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.