Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/261976
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.descriptionOrientador: Antônio Augusto Fasolo Quevedopt_BR
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.format.extent175 p. : il.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.typeDISSERTAÇÃOpt_BR
dc.titleDecomposição de sinais eletromiográficos de superfície misturados linearmente utilizando análise de componentes independentespt_BR
dc.title.alternativeDecomposition of linearly mixed surface electromyographic signals using independent component analysispt_BR
dc.contributor.authorAlmeida, Tiago Paggi dept_BR
dc.contributor.advisorFasolo Quevedo, Antonio Augusto, 1970-pt_BR
dc.contributor.advisorQuevedo, Antônio Augusto Fasolopt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computaçãopt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Engenharia Elétricapt_BR
dc.subjectEletromiografiapt_BR
dc.subjectProcessamento e detecção de sinaispt_BR
dc.subjectEntropia (Teoria da informação)pt_BR
dc.subjectTeoria da estimativa - Processamento de dadospt_BR
dc.subjectEngenharia biomédicapt_BR
dc.subject.otherlanguageElectromyographyen
dc.subject.otherlanguageDetection and signal processingen
dc.subject.otherlanguageEntropy (Information theory)en
dc.subject.otherlanguageTheory of estimation - Data processingen
dc.subject.otherlanguageBiomedical engineeringen
dc.description.abstractResumo: A eletromiografia e uma pratica clinica que permite inferir sobre a integridade do sistema neuromuscular, o que inclui a analise da unidade funcional contrátil do sistema neuromuscular, a unidade motora. O sinal eletromiografico e um sinal elétrico resultante do transiente iônico devido potenciais de ação de unidades motoras capturados por eletrodos invasivos ou não invasivos. Eletrodos invasivos capturam potenciais de ação de ate uma única unidade motora, porem o procedimento e demorado e incomodo. Eletrodos de superfície permitem detectar potenciais de ação de modo não invasivo, porem resultam na mistura de potenciais de ação de varias unidades motoras, resultando em um sinal com aparência de ruído aleatório, dificultando uma analise. Técnicas de Separação Cega de Fontes, como Analise de Componentes Independentes, tem se mostrado eficientes na decomposição de sinais eletromiograficos de superfície nos constituintes potenciais de ação de unidades motoras. Este projeto tem como objetivo desenvolver um protótipo capaz de capturar sinais mioeletricos de superfície e analisar a viabilidade da separação de sinais eletromiograficos intramusculares misturados linearmente, utilizando Analise de Componentes Independentes. O sistema proposto integra uma matriz de eletrodos com ate sete canais, um modulo de pré-processamento, um software para controle da captura dos sinais eletromiograficos de superfície e o algoritmo FastICA em ambiente MATLABR para separação dos sinais eletromiograficos. Os resultados mostram que o sistema foi capaz de capturar sinais eletromiograficos de superfície e os sinais eletromiograficos intramusculares misturados linearmente foram separados de forma confiávelpt
dc.description.abstractAbstract: Electromyography is a clinical practice that provides information regarding the physiological condition of the neuromuscular system, which includes the analysis of the contractile functional unit of the neuromuscular system, known as motor unit. The electromyographic signal is an electrical signal resultant from ionic transient regarding motor unit action potentials captured by invasive or non-invasive electrodes. Invasive electrodes are able to detect action potentials of even one motor unit, although the procedure is time consuming and uncomfortable. Surface electrodes enable detecting action potential noninvasively, although the detected signal is a mixture of action potentials from several motor units within the detection area of the electrode, resulting in a complex interference pattern which is difficult to interpret. Blind Source Separation techniques, such as Independent Component Analysis, have proven effective for decomposing surface electromyographic signals into the constituent motor unit action potentials. The objective of this project was to develop a system in order to capture surface myoelectric signals and to analyze the viability for decomposing intramuscular myoelectric signals that were mixed linearly, using independent component analyzes. The system includes an electrode matrix with up to seven channels, a preprocessing module, a software for controlling surface myoelectric signals capture, and the FastICA algorithm in MATLABR for the intramuscular myoelectric signals decomposition. The results show that the system was able to capture surface myoelectric signals and was capable of decomposing the intramuscular myoelectric signals that were previously linearly mixeden
dc.publisher[s.n.]pt_BR
dc.date.issued2012pt_BR
dc.identifier.citationALMEIDA, Tiago Paggi de. Decomposição de sinais eletromiográficos de superfície misturados linearmente utilizando análise de componentes independentes. 2012. 175 p. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/261976>. Acesso em: 20 ago. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreedisciplineEngenharia Biomedicapt_BR
dc.description.degreenameMestre em Engenharia Elétricapt_BR
dc.contributor.committeepersonalnameDuarte, Leonardo Tomazelipt_BR
dc.contributor.committeepersonalnameCosta, Eduardo Tavarespt_BR
dc.date.available2018-08-20T12:21:10Z-
dc.date.accessioned2018-08-20T12:21:10Z-
dc.description.provenanceMade available in DSpace on 2018-08-20T12:21:10Z (GMT). No. of bitstreams: 1 Almeida_TiagoPaggide_M.pdf: 6663822 bytes, checksum: bdc5918b5983a84b46acf03bb9096cc7 (MD5) Previous issue date: 2012en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/261976-
Appears in Collections:FEEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
Almeida_TiagoPaggide_M.pdf6.51 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.