Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/258589
Full metadata record
DC FieldValueLanguage
dc.contributor.CRUESPUNIVERSIDADE ESTADUAL DE CAMPINASpt_BR
dc.descriptionOrientador: Lucila Chebel Labakipt_BR
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismopt_BR
dc.format.extent149 p. : il.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.typeDISSERTAÇÃOpt_BR
dc.titleA influência do sombreamento do entorno na etiqueta de eficiência energética de edifício comercialpt_BR
dc.title.alternativeThe influence of surrounding shading on the labelling of energy efficiency of a commercial buildingpt_BR
dc.contributor.authorFernandes, Luciana Oliveira, 1984-pt_BR
dc.contributor.advisorLabaki, Lucila Chebel, 1943-pt_BR
dc.contributor.institutionUniversidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismopt_BR
dc.contributor.nameofprogramPrograma de Pós-Graduação em Engenharia Civilpt_BR
dc.subjectEficiência energéticapt_BR
dc.subjectIluminação naturalpt_BR
dc.subjectConforto térmicopt_BR
dc.subject.otherlanguageEnergy Efficiencyen
dc.subject.otherlanguageDaylightingen
dc.subject.otherlanguageThermal comforten
dc.description.abstractResumo: O elevado consumo de energia elétrica pelas edificações brasileiras e o potencial de conservação de energia motivou a criação do "Programa Nacional de Eficiência Energética em Edificações" - PROCEL Edifica - a fim de avaliar e classificar o nível de eficiência energética desses edifícios. A consideração do entorno ao avaliar o nível de eficiência energética de um edifício pelo método da simulação, segundo os "Requisitos Técnicos da Qualidade para o Nível de Eficiência Energética de Edifícios Comerciais, de Serviços e Públicos" (RTQ-C), é opcional. Contudo, pesquisas destacam a influência da geometria urbana no desempenho energético das edificações. Nesta pesquisa foi analisada a influência do entorno sobre o uso da iluminação natural e sobre a etiqueta de eficiência energética de uma edificação comercial, através da simulação computacional. Para isso um modelo hipotético foi simulado nos softwares EnergyPlus e Daysim sob diferentes configurações de entorno e três sistemas de iluminação artificial. O primeiro permanece ligado durante o período de ocupação, o segundo é acionado pelo usuário quando necessário e o terceiro é utilizado por usuários passivos, mas controlado por dimmers. A metodologia utilizada para avaliação do nível de eficiência do edifício se baseia na recomendação do RTQ-C que consiste em comparar o consumo de energia do edifício proposto com edifícios similares cujas características correspondem aos níveis de eficiência. Tomando como referência os modelos cuja iluminação artificial permanece acesa durante todo o período de ocupação, os modelos com sistema controlado por interruptor apresentou uma economia média de 71% no consumo com iluminação e 35% no consumo total. O sistema com dimmers resultou em uma economia média de 50% e 23% respectivamente. No caso estudado, ambos os sistemas permitiram elevar o nível de eficiência energética do edifício propostopt
dc.description.abstractAbstract: The high energy consumption of Brazilian buildings and the potential of energy savings have stimulated the establishments of the "National Program for Energy Efficiency of Buildings" - PROCEL Edifica - which evaluates and classifies the level of energy efficiency of these buildings. The "Quality Technical Requirements for the Energy Efficiency Level of Commercial, Services and Public Buildings" (RTQ-C) considers the modeling of the surroundings of the building optional to evaluate its energy efficiency by computational simulation. Nevertheless, researches indicate that urban geometry influences the energy performance of buildings. In this research it was analyzed the influence of the surroundings on the use of daylight in a non-residential building and thereafter on its energy efficiency label by means of computer simulation. For this purpose, a theoretical model of a non-residential building was simulated using the softwares Energy Plus and Daysim with different surroundings and three distinct electric lighting systems. The first one remains active during working hours. The second is activated by the user when needed, and the last one is triggered by passive users but controlled by dimmers. The methodology to evaluate the level of energy efficiency is based on the RTQ-C by which the energy consumption of the proposed building must be compared with similar buildings whose technical features match different levels of efficiency. With reference to the first system, the system controlled by the user resulted in an average economy of 71% on lighting annual consumption and 35% on total annual consumption. The dimmer system had an average economy of 50% and 23% respectively. In this case, both of the systems allowed raising the level of energy efficiency of the theoretical modelen
dc.publisher[s.n.]pt_BR
dc.date.issued2012pt_BR
dc.identifier.citationFERNANDES, Luciana Oliveira. A influência do sombreamento do entorno na etiqueta de eficiência energética de edifício comercial. 2012. 149 p. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Campinas, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/258589>. Acesso em: 20 ago. 2018.pt_BR
dc.description.degreelevelMestradopt_BR
dc.description.degreedisciplineArquitetura e Construçãopt_BR
dc.description.degreenameMestre em Engenharia Civilpt_BR
dc.contributor.committeepersonalnameCaram, Rosana Mariapt_BR
dc.contributor.committeepersonalnameWestphal, Fernando Simonpt_BR
dc.date.available2018-08-20T07:36:30Z-
dc.date.accessioned2018-08-20T07:36:30Z-
dc.description.provenanceMade available in DSpace on 2018-08-20T07:36:30Z (GMT). No. of bitstreams: 1 Fernandes_LucianaOliveira_M.pdf: 4185533 bytes, checksum: 77ac20bdb30c73e7e2c896ddaae5d13a (MD5) Previous issue date: 2012en
dc.identifier.urihttp://repositorio.unicamp.br/jspui/handle/REPOSIP/258589-
Appears in Collections:FEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
Fernandes_LucianaOliveira_M.pdf4.09 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.