Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/258576
Type: TESE
Title: Treliça tubular mista com múltiplos painéis Vierendeel
Title Alternative: Composite hollow truss with multiple Vierendeel panels
Author: Silva, Augusto Ottoni Bueno da
Advisor: Pinto Junior, Newton de Oliveira, 1951-
Junior, Newton de Oliveira Pinto
Abstract: Resumo: As treliças mistas em aço-concreto, alternativas bastante eficientes para vencer grandes vãos, são geralmente empregadas em edifícios comerciais e industriais, e, em pontes ferroviárias e rodoviárias. Em muitos casos, para que se possibilite a passagem de dutos, dificultada nos quadros com presença de diagonais, e construído um painel Vierendeel central; porem, em algumas situações, este único painel pode ser insuficiente, necessitando-se então a criação de novos painéis para satisfazer o uso que se pretende dar a construção. Neste sentido, o objetivo do estudo foi determinar através de um procedimento de calculo analítico e modelagens elástica bi-dimensional e plástica tri-dimensional, a capacidade resistente e o modo de ruptura de uma treliça tubular mista bi-apoiados com 15 metros de vão, sendo todo o terço central constituído por painéis Vierendeel. Em seguida, mantendo-se o vão de 15 metros e os perfis estipulados no dimensionamento, foi feita uma parametrização dos resultados para estruturas com 3, 7, 9 e 13 painéis. O estudo, desenvolvido para cargas de escritório, apontou a proporção vão/3 - vão/3 - vão/3 como a ideal para a relação entre trechos treliçado - Vierendeel - treliçado, pois ao se aumentar a proporção do trecho central ocupado pelos painéis Vierendeel, os novos sistemas perdem muita rigidez passando a não suportar mais a carga estipulada no projeto. Alem disso, podem passar a apresentar deslocamentos verticais excessivos e resistência às forcas cortantes externas atuantes sobre os painéis insuficiente

Abstract: The steel-concrete composite trusses, an efficient alternative to overcome large spans, are generally used in commercial and industrial buildings, and rail and road bridges. In many cases, in order to enable the passage of ducts, with complications in the frames with the presence of diagonals, a central Vierendeel panel is built, but in some situations, if this single panel may be insufficient, then one would need to create new panels to meet the intended use to build. In this case, the objective of the study was to determine, through analytical calculation, two-dimensional elastic modeling and three-dimensional plastic modeling, the bearing capacity and failure mode of a bi-supported truss with a 15 meter span, and the entire central third consisting of Vierendeel panels. Then, keeping the span of 15 meters and the sections determined in the design, a parameterization of the results was made for structures having 3, 7, 9 and 13 panels. The study developed for office loads, found the proportion span/3 - span/3 - span/3, as the ideal relationship for the truss - Vierendeel - truss lengths, because by increasing the proportion of the length occupied by the central Vierendeel panels, the new system loses stiffness and no longer support the load stipulated in the project. Furthermore, they can start presenting excessive vertical displacements and insufficient resistance to external shear forces acting on the panels
Subject: Estruturas metálicas
Treliças (Construção civil)
Construção mista
Language: Português
Editor: [s.n.]
Date Issue: 2013
Appears in Collections:FEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
Silva_AugustoOttoniBuenoda_D.pdf10.37 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.