Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/258530
Type: TESE
Title: Avaliação de atenuadores de ruido passivos resistivos para grupos geradores de energia
Title Alternative: Evaluation of passive resistive silencers of noise for energy generators
Author: Araujo, Nilza Maria Coradi de
Advisor: Bertoli, Stelamaris Rolla, 1958-
Abstract: Resumo: Esse trabalho tem por objetivo avaliar o desempenho acústico de atenuadores de ruído para grupos geradores de energia. Geradores de energia a diesel são equipamentos extremamente ruidosos e para tratar acusticamente um gerador é necessário, entre outras coisas, o tratamento das aberturas para ventilação. Essas aberturas são geralmente tratadas com atenuadores (silenciadores) de ruído .Existem vários tipos de silenciadores os mais comuns são os passivos resistivos que se caracterizam pelo uso de material absorvente nas paredes internas do duto. Os silenciadores objeto de estudo deste trabalho foram os dutos retangulares com células divisórias paralelas. Para a realização das medidas de desempenho acústico dos silenciadores foi utilizada a metodologia descrita na ISO 11 820 Acoustics - Measurements on Silencers in situo Essa norma apresenta dois parâmetros de avaliação de desempenho acústico: perda por transmissão e perda por inserção. Para realização da avaliação de desempenho acústico, foram construídos e testados 22 tipos diferentes de silenciadores, alterando as dimensões das lamelas, o tamanho do duto e a densidade e espessura do material absorvente. Os resultados das avaliações mostraram que a espessura das lamelas e o comprimento do duto têm uma maior influência na eficiência do atenuador do que a densidade do material absorvente. Realizou-se, ainda, uma análise comparativa entre eficiência e custo entre os silenciadores avaliados. Os resultados dessa analise permitiram estabelecer quais silenciadores que apresentaram a melhor relação custo benefício, isto é, melhor desempenho acústico e menor custo.

Abstract: The objective this work is to evaluate the acoustic performance of the silencers of noise for energy group generators. Generators of energy to Diesel are extremely noisy equipments. For acoustic treatment of a generator it is necessary, among other things, the treatment of the openings of ventilation. The openings are generally treated with silencers of noise. There are several types of silencers, the most common are the passive resistive. The passive resistive silencers are characterized by the use of absorbent material in the internal walls of the lined ducts. The silencer object of the study this work is the rectangular lined duct of the parallel bafflers. For the accomplishment of the measures of acoustic performance of the silencers was used the methodology described in ISO 11 820 Acoustics Measurements on Silencers in situ. The ISO 11 820 standard presents two parameters of evaluation of acoustic performance: transmission loss and insertion loss. For accomplishment of the evaluation of acoustic performance, were built and tested 22 types of different silencers, altering the dimensions of the bafflers the size of the duct and the density and thickness of the absorbent material. The results of the evaluations showed that the thickness of the bafflers and the length of the duct have a larger influence in the efficiency of the silencer than the density of the absorbent material. It was also made a comparative analysis between the efficiency and the cost among the appraised silencer. The results of that analyze allowed to establish which silencer that presented the best cost/benefit relation or the better acoustic performance and lower cost.
Subject: Controle de ruído
Poluição sonora
Engenharia acústica
Language: Português
Editor: [s.n.]
Date Issue: 2004
Appears in Collections:FEC - Tese e Dissertação

Files in This Item:
File SizeFormat 
Araujo_NilzaMariaCoradide_M.pdf12.8 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.