Title: Tratamento de agua subterranea contaminada com BTEX utilizando fotocatalise heterogenea
Title Alternative: Treatment of contaminated groundwater with BTEX using heterogene
Author: Donaire, Patricia Pulcini Rosvald
Advisor: Caballero, Nelson Eduardo Duran
Abstract: Resumo: O presente trabalho trata do desenvolvimento de um reator tubular fotocatalítico aplicado ao tratamento de águas superficiais e subterrâneas contaminadas com compostos orgânicos voláteis, mais especificamente benzeno, tolueno, etilbenzeno e xileno (BTEX). O reator opera com recirculação da amostra e é constituído por dois catalisadores semicondutores, o dióxido de titânio e o dióxido de zircônio (TiO2/ZrO2). Estes catalisadores foram depositados sobre substratos de vidro na forma de filme misto e ativados com luz artificial proveniente de 2 lâmpadas de luz negra de 15 W cada, representando uma intensidade luminosa total de 3,6 mW cm. Os resultados demonstraram a viabilidade da utilização da fotocatálise heterogênea através da deposição de 15 camadas do filme misto sobre a matriz de vidro. A irradiação de água deionizada contaminada com 10 mg L de BTEX resultou em 95,9% de remoção destes compostos em pH 6,6 e vazão de recirculação de 280 mL min , onde somente o benzeno não alcançou o limite permitido pela legislação. A quantificação dos analitos foi realizada utilizando-se microextração em fase sólida (SPME). Observou-se uma cinética de pseudo-primeira ordem sendo a concentração inicial um fator limitante na taxa de degradação. A acetofenona foi a espécie intermediária detectada durante o processo fotocatalítico. No experimento de toxicidade utilizando Daphnia similis como organismo teste, a remoção de toxicidade foi atingida após 30 min de tratamento de água contaminada com gasolina onde o CE50-48 h inicial médio foi de 14,1% atingindo um CE50-48 h final médio de 84,3%

Abstract: The present work deals with the development of a photocatalytic tubular reactor to treat superficial and groundwaters contaminated with organic volatile compounds, more specifically benzene, toluene, ethylbenzene and xylene (BTEX). The reactor was operated with sample recirculation and it was constituted by two semiconductors catalysts, the titanium dioxide and the zirconium dioxide (TiO2/ZrO2). These catalysts were deposited over glass substrate in the form of mixed film and activated with artificial light originated from two 15 W black light lamps representing an average light intensity of 3.6 mW cm. The results showed the viability of heterogeneous photocatalysis using a deposition of 15 mixed film layers over the glass matrix. The photodegradation of deionized water contaminated with 10 mg L of BTEX gave a 95.9% of BTEX removal at pH 6.6 with a recirculation flow of 280 mL min . Among the other components of BTEX, only the benzene did not reach the permitted limit by legislation. The analytes were quantified by solid phase microextraction (SPME). The kinetic of pseudo-first order was observed and being the initial concentration a limiting factor in the degradation rate. The acetophenone was the intermediate species detected during photocatalytic process. In the toxicity experiment using Daphnia similis as organism test, the toxicity removal was reached after 30 min of treatment of contaminated water with gasoline where the initial average CE50-48 h was 14.1 % and reaching a final average CE50-48 h of the 84.3%
Subject: Fotocatálise heterogênea
Águas subterrâneas
BTEX
Dióxido de titânio
Language: Português
Editor: [s.n.]
Date Issue: 2007
Appears in Collections:IQ - Tese e Dissertação

Files in This Item:
File SizeFormat 
Donaire_PatriciaPulciniRosvald_D.pdf1.34 MBAdobe PDFView/Open